跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+0新增论文
+0其中 AI 相关
+0已有论文修订
+93新增 AI 导读

arXiv 最近完成扫描:2026-11-16 01:34 · 全站最近入库:2026-11-14 15:09各信源进度 →

统计口径与数据新鲜度

统计 2026-11-15 10:10 — 2026-11-16 10:10(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-16 01:34最近发现新增版本:2026-11-14 15:09库内论文最新更新时间:2026-11-13 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

23,348 已收录论文19,580 AI 相关6,729 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 2 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-16 01:33(北京时间)
新论文 · v1arXiv:2611.12044

Leveraging High-Activity Post-Therapeutic I-131 Scans for Deep Learning Reconstruction of Extremely Sparse Planar Images in Differentiated Thyroid Cancer

Boyang Pan, Hang Yang, Jianchen Pan, Cui Gan, Lanxi Zhang, Hongmin Li, Nan-Jie Gong

原文摘要

Background: Diagnostic I-131 whole-body planar imaging in differentiated thyroid cancer (DTC) is count-limited by low administered activity, and quality worsens under rapid acquisition. Models trained on such data struggle because their targets lack photon statistics. Purpose: To test whether high-quality post-therapeutic (PT) I-131 scans can serve as superior training references for enhancing sparse diagnostic planar images, using transfer learning and input-image addition. Methods: In this single-center prospective study, 111 patients were enrolled in PT training (n = 19), diagnostic follow-up (FU) training (n = 58), and FU paired test (n = 34) cohorts. Five Restormer-based models were trained: FU_DLx2 on FU labels; PT_DLx2 transfer-learned on PT data; PT_DLx1+ and PT_DLx2+ with input-image addition; PT_DLx6 as a PT-only reference. Test-time processing used two-step denormalization and Poisson re-scaling to preserve noise statistics. Quality was assessed by PSNR, SSIM, and a blinded dual-reader evaluation of all 34 test-cohort patients. Results: PT_DLx2 achieved the highest PSNR (34.4 +/- 3.6 dB) and SSIM (0.81 +/- 0.07). PT_DLx1+ and PT_DLx2+ were comparable (33.8 and 33.3 dB; SSIM 0.80). FU_DLx2 ranked below the unprocessed fast scan (30.3 vs. 32.0 dB; 0.76 vs. 0.79). Subjectively, PT_DLx2+ scored highest in image quality (4.54 +/- 0.60) and diagnostic confidence (4.54 +/- 0.60), surpassing the reference standard (4.19 +/- 0.83 and 4.31 +/- 0.81; P = 0.005 and P = 0.008). FU_DLx2 and PT_DLx6 scored lowest. Conclusion: Count-rich PT scans provide effective training priors for reconstructing extremely sparse images. Input-image addition and cross-domain transfer learning from PT data outperformed direct training on count-limited diagnostic data, supporting 2x scan acceleration with quality matching or exceeding the unaccelerated standard scan for selected PT-derived configurations.

eess.IV · cs.CV · physics.med-ph

新论文 · v1arXiv:2611.08954

MetricPose: Flexible 3D Human Pose Estimation with Depth and Geometric Cues

Shifan Zhu, Sabad Modi, Hang Yang, Arushi Agrawal, Steven Gao, Meghan Huber, Nathan Wycoff, Donghyun Kim

原文摘要

In this paper, we present a 3D human pose estimator that predicts metrically accurate human joint positions in the camera coordinate frame. This task requires recovering the configuration of the body joints, scale, and metric camera-local placement. In monocular images, body size and camera distance are coupled through perspective projection and therefore cannot be determined uniquely from image alone. This ambiguity can be reduced by combining three complementary sources of information: learned RGB priors, direct depth measurements, and geometric constraints (e.g., ground contact) from the environment. We extend a pretrained full-body estimator with optional metric depth and geometry-processing modules that improve camera-distance estimation and depth-guided body refinement while preserving RGB-only operation. The resulting unified model supports RGB, RGB-Ground, and RGB-D using shared learned parameters. Unlike pelvis-relative error, camera-local error also measures placement relative to the camera. Compared with the existing foundation model SAM 3D Body, our methods with RGB, RGB-Ground, and RGB-D modes reduce camera-local joint-position error by 12.16%, 31.00% and 54.61% respectively.

cs.CV