跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+427新增论文
+334其中 AI 相关
+73已有论文修订
+92新增 AI 导读

arXiv 最近完成扫描:2026-11-23 01:07 · 全站最近入库:2026-11-23 14:16各信源进度 →

统计口径与数据新鲜度

统计 2026-11-22 17:29 — 2026-11-23 17:29(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-23 01:07最近发现新增版本:2026-11-23 14:16库内论文最新更新时间:2026-11-21 02:58

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

29,585 已收录论文24,515 AI 相关9,167 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 4 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-23 01:05(北京时间)
版本更新 · v3arXiv:2608.04196

SiMDex: Mining Similar Egocentric Videos for Cross-Embodiment Dexterous Manipulation

Nie Lin, Takehiko Ohkawa, Sijin Chen, Ruoshi Wen, Zhuohang Li, Liqun Huang, Zhengming Zhu, Yiming Bao 等 13 位作者

原文摘要

Recent years have witnessed an explosive trend of scaling ego-centric human videos for robot manipulation, yet it remains unclear which data actually benefits dexterous manipulation. We present SiMDex, a similarity-based data mining framework that casts human data selection for VLA post-training in dexterous manipulation as a recommendation problem. For each robot demonstration, SiMDex runs a recall-ranking-re-ranking cascade over ~32M egocentric human samples: two stages, recall and ranking, select a task-relevant subset in a morphology-agnostic action space, and re-ranking verifies it on pixels, with no change to VLA architecture or training. Against a strong baseline trained with an equal amount of randomly sampled human data, SiMDex uses only ~1.49M mined samples (<5% of the pool) yet improves the overall success rate from 47.7% to 61.7%, showing that selective curation outperforms indiscriminate data mixing.

cs.RO · cs.CV · cs.LG

新论文 · v1arXiv:2611.13425

Prompt2Echo (P2Echo): Text-Prompted Multi-View Echocardiography Segmentation with One Model

Moein Heidari, Alvin Kimbowa, Mahdi Tabatabaei, Afshin Bozorgpour, Sina Ghorbani Kolahi, River Jiang, Wenjin Chen, David J. Foran 等 11 位作者

原文摘要

Automated segmentation in multi-view echocardiography is essential for comprehensive cardiac assessment, yet remains challenging due to substantial anatomical and appearance variability across standard acoustic windows. In this paper, we present P2Echo, a unified framework capable of segmenting diverse cardiac structures across multiple standard echocardiographic views using a single model controlled by structured view-aware text prompts. Unlike recent foundation model adaptations that rely on implicit latent priors, P2Echo explicitly conditions the segmentation process via a novel Dynamic Image-Text Alignment (DyITA) module. DyITA integrates a differentiable routing mechanism and token differential operators to dynamically modulate decoder features according to the requested view and target structure. This allows the network to adaptively switch its processing pathways for different views without architectural changes. Extensive experiments on a large-scale internal dataset (seen during training) and held-out evaluation on three external datasets demonstrate that P2Echo matches or exceeds both view-specific specialists and state-of-the-art universal models at a fraction of their computational cost, offering an efficient, controllable solution for multi-plane cardiac analysis. Code is available at: https://github.com/moeinheidari7829/P2Echo.

cs.CV

新论文 · v1arXiv:2611.06627

Interactive World Simulation with Cosmos for Physical AI

NVIDIA, :, Anis Ahmad, Jon Allen, Malik Aqeel Anwar, Jesse Archer, Maciej Bala, Piotr Barejko 等 90 位作者

原文摘要

We present a shared framework that adapts Cosmos world foundation models for real-time interactive world simulation in Physical AI. By streaming visual observations in response to actions and scene controls, the framework enables users and embodied agents to interact with evolving virtual environments. It supports both predicting the visual consequences of actions and generating observations from physical state maintained by an external simulator. We demonstrate this approach across camera navigation and robot manipulation, controllable video transfer, and multi-view autonomous vehicle (AV) simulation. These examples provide a shared foundation for developing interactive virtual environments for Physical AI training and evaluation. Our code and model checkpoints are available at https://github.com/nvidia/cosmos and https://huggingface.co/collections/nvidia/cosmos3-examples. The project website is available at https://research.nvidia.com/labs/cosmos-lab/cosmos-simulation.

cs.AI · cs.CV · cs.LG · cs.RO

新论文 · v1arXiv:2611.03360

Every Pixel Is an Option: A System One Model for Medical Ultrasound Biometry

Moein Heidari, Junbo Rao, Yudan Chen, Yasamin Medghalchi, River Jiang, Wenjin Chen, David J. Foran, Jasmine Grewal 等 9 位作者

原文摘要

**Purpose:** Ultrasound biometry is widely used across various clinical applications, including prenatal and cardiac examinations, to obtain quantitative measurements by placing calipers at anatomical landmarks. However, these measurements remain subject to interoperator variability as they rely largely on manual caliper placement. Conventional methods often use specialized prediction heads for different ultrasound tasks, whereas vision-language models offer flexibility through text instructions. However, direct coordinate prediction does not explicitly model spatial likelihood distributions, limiting the representation of localization ambiguity. **Methods:** We propose Kev-Bio, a vision-language model that uses clinical measurement questions to guide ultrasound landmark detection. Inspired by System One decision models, Kev-Bio uses decision representations of the language model to generate queries for each caliper endpoint. These queries are matched against shared dense ultrasound features to produce spatial probability maps, from which landmark coordinates and clinical measurements are derived. The model is trained end-to-end using both landmark localization and clinical measurement losses. **Results:** On the nine-view FU/GU Biometry 2026 dataset, Kev-Bio achieves a mean radial error (MRE) of 22.50 pixels and a clinical measurement mean absolute error (MAE) of 15.38, outperforming the compared baselines in overall performance. **Conclusion:** These results demonstrate the effectiveness of Kev-Bio for ultrasound landmark detection and clinical measurement across different anatomical views. Our code and models are available at https://github.com/moeinheidari7829/Kev-Bio.

cs.CV · cs.LG