跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+0新增论文
+0其中 AI 相关
+0已有论文修订
+0新增 AI 导读

arXiv 最近完成扫描:2026-11-27 19:13 · 全站最近入库:2026-11-26 12:29各信源进度 →

统计口径与数据新鲜度

统计 2026-11-27 07:44 — 2026-11-28 07:44(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-27 19:13最近发现新增版本:2026-11-26 12:29库内论文最新更新时间:2026-11-26 08:00

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

34,433 已收录论文28,422 AI 相关10,935 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 2 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-27 19:11(北京时间)
新论文 · v1arXiv:2611.21419

Quality and Similarity Indicators for Video-Based Heart Rate and Respiratory Rate Fusion: A Controlled Evaluation

Nhi Nguyen, Le Nguyen, Manuel Lage Cañellas, Miguel Bordallo López, Constantino Álvarez Casado

原文摘要

Camera-based heart rate (HR) and respiratory rate (RR) estimates vary in reliability from window to window, and a common remedy is to fuse several extraction methods with weights from reference-free signal quality indicators. However, few studies test whether these indicators identify the most accurate method in each window or outperform simpler fusion. We evaluate 11 quality indicators and 8 inter-method similarity measures for fusing 7 HR and 10 RR extractors on four public datasets (75 test subjects). Filters, indicator directions, weighting parameters and a learned ridge baseline are selected on a separate five-subject set before testing. Fusion is compared with equal averaging, a constant typical-rate predictor, the best single method selected in advance and in hindsight, and a per-window oracle with a permutation-based null, using subject-level bootstrap confidence intervals. For HR, quality-weighted fusion reduced mean absolute error by 10.9% [5.2, 18.4] relative to averaging and by 15.6% [8.1, 23.1] relative to the method selected in advance, and was statistically indistinguishable from the best method selected in hindsight. Weighting methods by their agreement did not improve on averaging. For RR, the indicators could not identify the more accurate estimates: sharpened quality weighting increased error (-2.6% [-4.8, -0.8]), fused estimates were uncorrelated with the reference (r <= 0.22), and averaging was less accurate than the typical-rate predictor (-3.1% [-6.1, -0.4]). With a second respiratory reference, apparent RR gains reflected estimates moving toward its typical rate. Quality-guided fusion is worthwhile for video HR; for RR, 30-s windows improved estimates but not fusion.

cs.CV

版本更新 · v2arXiv:2508.18787

Design, Implementation and Evaluation of a Real-Time Remote Photoplethysmography (rPPG) Acquisition System for Non-Invasive Vital Sign Monitoring

Constantino Álvarez Casado, Sasan Sharifipour, Manuel Lage Cañellas, Nhi Nguyen, Le Nguyen, Miguel Bordallo López

原文摘要

The growing integration of smart environments and low-power computing devices, coupled with mass-market sensor technologies, is driving advancements in remote and non-contact-based physiological monitoring. However, deploying these systems in real-time on resource-constrained platforms introduces significant challenges related to scalability, interoperability, and performance. This paper presents a computationally efficient real-time remote photoplethysmography (rPPG) system, designed to extract physiological signals, such as heart rate, respiratory rate, and oxygen saturation (SpO2), from facial video streams. The system is built on the Face2PPG pipeline, which processes video frames sequentially for rPPG signal extraction and analysis, while leveraging a multithreaded architecture to manage video capture, real-time processing, network communication, and graphical user interface updates concurrently. This design targets continuous operation at 30 frames per second (FPS), with adaptive feedback through a collaborative user interface to guide optimal signal capture conditions. The network interface includes both an HTTP server for continuous video streaming and a RESTful API for on-demand vital sign retrieval. To ensure accurate performance despite limited computational resources, we use a hybrid programming model combining Functional Reactive Programming (FRP) and the Actor Model, allowing event-driven processing and efficient task parallelization. We evaluate HR accuracy on three public datasets (COHFACE, LGI-PPGI, and UBFC-RPPG), and conduct preliminary evaluations of RR on COHFACE and SpO2 on PURE. We also assess the processing time and end-to-end operation of the system on two computers, including live HR and SpO2 agreement with a medical-grade fingertip pulse oximeter across five 10-minute sessions. Our work addresses key challenges in real-time contactless biosignal monitoring.

cs.CV