跳到正文
研踪PaperTrail

YOUR RESEARCH, IN SIGHT

让下一篇重要论文,不再错过。

覆盖计算机全学科,以 AI 为快捷入口。关注方向、作者和关键词,把发现变成持续的研究积累。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+1673新增论文
+1257其中 AI 相关
+198已有论文修订
+100新增 AI 导读

arXiv 最近完成扫描:2026-11-14 02:49 · 全站最近入库:2026-11-13 20:44各信源进度 →

统计口径与数据新鲜度

统计 2026-11-13 02:52 — 2026-11-14 02:52(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-14 02:49最近发现新增版本:2026-11-13 20:44库内论文最新更新时间:2026-11-13 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

23,348 已收录论文19,580 AI 相关6,727 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-14 02:48(北京时间)
新论文 · v1arXiv:2611.16393

TransXplainRRG: A Radiologist-Evaluated LVLM for Chest Radiograph Report Generation

Chayan Mondal, Duc-Son Pham, Tele Tan, Ashu Gupta, Vincent T. Y. Tiong, Shreya Ghosh, Tom Gedeon

原文摘要

Recent advancements in Large Vision-Language Models (LVLM) enhance X-ray report generation, but often neglect clinical context, overlook workflow integration, and lack explainability, which hinders clinical adoption due to interpretability and reliability concerns. This paper addresses the dual challenges of performance and expert explainability in automated X-ray report generation for clinical AI applications. Our proposed approach, TransXplainRRG, utilises an off-the-shelf Swin Transformer model along with a transformer-based text encoder that incorporates patient medical history to generate a radiology report. Further, we explore an expert-guided `inside-out' approach and extract only abnormal findings for radiology report refinement. Thus, this study bridges the gap between high-performance automation and interpretability critical for clinical practice by combining state-of-the-art transformer-based vision encoders, text encoders, and LLMs. TransXplainRRG is trained and tested on the large-scale MIMIC-CXR dataset and further evaluated on the unseen IU X-Ray dataset to demonstrate its generalizability and robustness. We employed the GREEN metric as a complementary measure of clinical consistency, achieving scores of 0.327 on MIMIC-CXR and 0.605 on IU X-Ray, both higher than those achieved by MAIRA-2 under the same evaluation setting. It also performed competitively across standard evaluation metrics, frequently matching or surpassing state-of-the-art models. Additionally, we introduce qualitative evaluation metrics developed from radiologists' viewpoints and conduct a preliminary radiologist evaluation on 100 generated reports to assess their clinical relevance. Quantitative and qualitative analyses further demonstrate the potential of our TransXplainRRG framework for reliable and explainable radiology report generation.

cs.CV · cs.AI