Exemplar-free continual learning seeks to minimize joint risk over all seen tasks, yet historical data are unavailable for direct optimization. We observe that, for classification, preserving the model's decisions on previously learned classes helps retain old knowledge. This motivates Decision-Preserving Regularization (DPR). Penalizing changes in all pairwise old-class logit margins reduces algebraically to a centered relative-logit penalty. We further apply spectral whitening to remove the classifier's spectral scale bias. Because the global classifier supplies the decision constraints for the next stage, it must remain calibrated across all seen classes despite the drift of stored old-class statistics during representation updates. We therefore fit a closed-form affine map from paired current-task features to transport old-class Gaussian means and covariances into the updated feature space, then calibrate the global classifier using these distributions and current-task features. Across CIFAR-100, Tiny-ImageNet, ImageNet-Subset, and ImageNet-1K under cold-start protocols, comparisons with state-of-the-art methods show that DPR achieves higher accuracy in most settings while remaining highly efficient. Code is available at https://github.com/bnufw/dpr.
Complete-or-reject reporting of surgical action triplets can discard a correctly identified instrument and action when the target is uncertain. We introduce instance-preserving graded semantic reporting, which separates instance selection from the choice of semantic detail. Each selected instance retains its predicted mask and labels while hierarchical correctness scores guide instrument (I), instrument-verb (IV), or complete instrument-verb-target (IVT) reporting. The utility-increment rule DELTA weighs the expected gain from finer reporting against its error cost. We compare three decision rules on 5,641 test frames from eight surgical videos using fixed predictions and scores. At the 10% development calibration target, DELTA retains correct partial reports for 80.0% of candidates rejected by a matched complete-or-reject baseline (5,329/6,662). Adding IV increases source-normalized weighted correct-report yield by 19.13 to 23.13 per 100 frames across all three rules relative to separately recalibrated I/IVT controls. Weighted reporting risk changes by -0.77 to +1.01 percentage points, with complete correct-triplet counts unchanged or reduced. Graded reporting makes partial surgical predictions available as localized descriptions, with an explicit trade-off between report utility and completeness.