跳到正文
研踪PaperTrail

YOUR RESEARCH, IN SIGHT

让下一篇重要论文,不再错过。

覆盖计算机全学科,以 AI 为快捷入口。关注方向、作者和关键词,把发现变成持续的研究积累。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+0新增论文
+0其中 AI 相关
+3已有论文修订
+100新增 AI 导读

arXiv 最近完成扫描:2026-11-14 18:17 · 全站最近入库:2026-11-14 15:09各信源进度 →

统计口径与数据新鲜度

统计 2026-11-13 20:16 — 2026-11-14 20:16(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-14 18:17最近发现新增版本:2026-11-14 15:09库内论文最新更新时间:2026-11-13 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

23,348 已收录论文19,580 AI 相关6,729 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-14 18:15(北京时间)
版本更新 · v2arXiv:2611.13168

RadRef: A Reference-Free Metric for Radiology Report Generation

Shelly Schwartz, Alan Ropp, Michael B. Sneider, Nur Yildirim, Cree M. Gaskin, Chirag Agarwal

原文摘要

AI-generated radiology reports are commonly evaluated against radiologist-authored references, limiting the applicability of standard reference-based metrics when no reference is available. We introduce RadRef, a reference-free metric that scores report claims against image-derived beliefs over a clinical finding vocabulary, weighted by relevance to the clinical indication. By evaluating findings beyond the report's stated claims, RadRef assesses omissions as well as unsupported assertions. On ReXVal, RadRef achieves $73.1\%$ agreement with radiologist rankings among non-tied same-radiograph report pairs, with $61.8\%$ pair coverage and $64.3\%$ tie-inclusive agreement. Its non-tied agreement is close to GREEN ($73.9\%$) and RadFact ($72.6\%$), with its strongest relative results on omissions. We further evaluate $100$ model-generated and $100$ radiologist-authored reports from $100$ MIMIC-CXR studies, independently annotated by two board-certified radiologists. On same-image omission rankings, RadRef attains Kendall's $τ_b = 0.295$, compared with $0.386$ between the readers. In separate paired comparisons across generated reports, no evaluated comparator significantly outperforms RadRef on omissions. The same image-grounded representation provides a false-finding readout, RadRef-FF, with $τ_b = 0.32$ on ReXVal and $0.29$ in the reader study. Controlled perturbations confirm that RadRef depends on the radiograph, report, and clinical indication. RadRef enables image-grounded evaluation before a radiologist-authored reference exists, supporting quality monitoring of report-generation systems in clinical settings, and complements reference-based metrics when one is available.

cs.LG