跳到正文
研踪PaperTrail

YOUR RESEARCH, IN SIGHT

让下一篇重要论文,不再错过。

覆盖计算机全学科,以 AI 为快捷入口。关注方向、作者和关键词,把发现变成持续的研究积累。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+1734新增论文
+1439其中 AI 相关
+88已有论文修订
+100新增 AI 导读

arXiv 最近完成扫描:2026-11-06 02:51 · 全站最近入库:2026-11-05 12:13各信源进度 →

统计口径与数据新鲜度

统计 2026-11-05 03:40 — 2026-11-06 03:40(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-06 02:51最近发现新增版本:2026-11-05 12:13库内论文最新更新时间:2026-11-05 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

15,949 已收录论文13,765 AI 相关3,571 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-06 02:49(北京时间)
新论文 · v1arXiv:2611.05741

OUCH: Objective, Uniform, Controlled Haptic Stimulation for Automated Neurological Assessment

Sherry Choi, Sitao Sunny Li, Joseph Romero, Lillian Chin, Ashwin G. Ramayya, Allison M. Okamura, Ava Chen

Motor responses evoked by noxious stimulation are used to assess neurological function in hospitalized patients with disorders of consciousness. In standard bedside assessments, these stimuli are applied manually, resulting in substantial variation in force, duration, frequency, and location. Here, we present OUCH (Objective, Uniform, Controlled Haptic stimulation), a wrist-worn device that uses pneumatic actuation to deliver noxious mechanical stimuli. OUCH combines stacked pneumatic pouch actuators, a rigid indenter, and a compliant spacer designed to buckle at a set load, so that the indenter contacts the skin only during actuation. We characterize the device using blocked force tests, clinician evaluation, finite element analysis, and a deformable pressure testbed, and benchmark it against a commercially available handheld pressure algometer. At 200 kPa pouch inflation pressure, our indenter concentrated its load into an estimated contact pressure of 18,500 kPa, over 25 times that of the algometer tip, while requiring less total force. On the deformable testbed, it localized deformation near the surface, while deformation at depth remained comparable to the algometer. As a result, in preliminary perceptual testing, our indenter elicited discomfort at approximately 89% lower applied force than the algometer, demonstrating the feasibility of evoking discomfort with a compact, wearable soft actuator. These results show that combining pneumatic actuation with designed contact geometry enables controlled, repeatable noxious stimulation at the wrist, providing a foundation for objective neurological assessment.

尚无 AI 解读,展示原文摘要

cs.RO
arXiv ↗PDF ↗