跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+1205新增论文
+949其中 AI 相关
+153已有论文修订
+59新增 AI 导读

arXiv 最近完成扫描:2026-11-18 04:28 · 全站最近入库:2026-11-18 12:34各信源进度 →

统计口径与数据新鲜度

统计 2026-11-17 13:29 — 2026-11-18 13:29(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-18 04:28最近发现新增版本:2026-11-18 12:34库内论文最新更新时间:2026-11-18 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

26,054 已收录论文21,703 AI 相关7,828 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-18 04:27(北京时间)
新论文 · v1arXiv:2611.01631

Zero-shot evaluation of open vision-language models as System 1 decision models on radiology tasks

Bradley J Erickson, Sara Salehi

原文摘要

Purpose: We compared two multimodal System 1 decision models, Clef 27B and d1 3B, with a traditional LLM (Qwen 3.8-27B) on seven radiology tasks covering text, radiographs, CT and MRI. Methods: Three models were compared: Clef, Qwen3.8-27B and d1. Three tasks were interpretation of text and 4 were detection of finding in images. The tasks were: 1. finding presence of finding in CT-RATE chest CT reports; 2. Presence of finding in PadChest chest radiograph reports; 3. the same 18 findings on CT-RATE chest CT but 3D volumes; 4. MR safety status of devices from AccessGUDID device records; 5. line and tube position on RANZCR CLiP chest radiographs; 6. motion-artifact severity on MR-ART T1-weighted brain MRI and 7. sequence identification on BraTS 2021 brain MRI. The primary endpoint was AUROC. There was no fine-tuning of the models on the tasks. Results: All models completed all tests without a failed request. All retrieved findings from reports almost perfectly (AUROC >0.95). Clef ranked higher than its Qwen backbone on CT-RATE volumes and RANZCR lower on MR-ART. The two did not differ on BraTS, GUDID or PadChest, and differed by 0.002 on CT-RATE reports. On BraTS, Clef correctly identified 90 of 100 FLAIR volumes while Qwen never chose it. d1 ranked lower than Clef on six of seven tasks. No model performed well on motion severity. Clef was faster per request than Qwen on tasks with many questions per input. d1 used 3 to 9 times less energy per request than Clef. Conclusions: System 1 models can perform important tasks in radiology with high accuracy, at lower compute cost than LLMs used in the usual way. When an LLM is constrained to a single answer token, its cost and performance is similar to System 1 models unless multiple questions are asked. A 3B System 1 model was close to the 27B models on report text but not on images. No model performed well on motion severity.

cs.CV · cs.AI