跳到正文
研踪PaperTrail

YOUR RESEARCH, IN SIGHT

让下一篇重要论文,不再错过。

覆盖计算机全学科,以 AI 为快捷入口。关注方向、作者和关键词,把发现变成持续的研究积累。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+3638新增论文
+2751其中 AI 相关
+108已有论文修订
+69新增 AI 导读

arXiv 最近完成扫描:2026-11-04 23:44 · 全站最近入库:2026-11-05 00:45各信源进度 →

统计口径与数据新鲜度

统计 2026-11-04 00:46 — 2026-11-05 00:46(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-04 23:44最近发现新增版本:2026-11-05 00:45库内论文最新更新时间:2026-11-04 08:00

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

12,315 已收录论文10,426 AI 相关3,088 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-04 23:39(北京时间)
版本更新 · v2arXiv:2610.10473

Label-free cell counting and viability prediction with brightfield imaging and deep learning

Amir Reza Vazifeh, Christian Zeigler, Sornanathan Meyyappan, Richard Jeske, Jason W. Fleischer

Cell viability assessment is a core requirement in cell culture systems, with critical applications in biopharmaceutical manufacturing and drug development. Conventionally, it is measured by adding membrane-impermeable dyes to a sample (a process called staining), which allows compromised cell membranes to be distinguished from intact ones. However, staining has several limitations: (a) chemical agents can perturb normal cellular processes of the cells being measured, (b) it is often ambiguous to assign viability to individual cells whose membrane integrity is only partially compromised, (c) photobleaching can undermine measurement accuracy over time when using fluorescent stains, and (d) staining cannot be performed in situ or in real time. Here, we show that (1) stained cells captured under brightfield imaging contain sufficient information to distinguish live and dead cells, and (2) cells captured under unstained brightfield imaging exhibit similar image features to their stained counterparts, enabling models trained on stained cells to generalize to unstained ones. We then report the development and validation of ViabiLens, an AI-assisted software tool for label-free cell viability analysis. ViabiLens combines a cell detection model for localizing individual cells with a convolutional neural network (CNN) classifier for live/dead prediction, paired with an interactive UMAP-based viewer for visualizing and exploring individual cells across the sample. Evaluated on Chinese Hamster Ovary (CHO) cells spanning a wide range of viability conditions, ViabiLens achieves a mean absolute error of 2.33\% on unstained samples against fluorescence-based reference measurements. The demo of ViabiLens software is available at https://amirrezavazifeh.github.io/ViabiLens-Project-Page/.

尚无 AI 解读,展示原文摘要

cs.CV · q-bio.CB
arXiv ↗PDF ↗