跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+479新增论文
+361其中 AI 相关
+64已有论文修订
+93新增 AI 导读

arXiv 最近完成扫描:2026-11-16 01:34 · 全站最近入库:2026-11-16 21:56各信源进度 →

统计口径与数据新鲜度

统计 2026-11-15 23:50 — 2026-11-16 23:50(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-16 01:34最近发现新增版本:2026-11-16 21:56库内论文最新更新时间:2026-11-14 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

23,827 已收录论文19,941 AI 相关6,922 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-16 01:33(北京时间)
版本更新 · v2arXiv:2606.12635

CD-RCM:面向反射共聚焦显微镜的可泛化连续深度新视角合成

CD-RCM: Generalizable Continuous-Depth Novel View Synthesis for Reflectance Confocal Microscopy

Tooba Imtiaz, Milind Rajadhyaksha, Kivanc Kose, Jennifer Dy

AI 速读 基于摘要

提出首个针对反射共聚焦显微镜(RCM)的前馈式新视角合成模型 CD-RCM,从稀疏深度采样的 RCM 层叠图像预测中间深度切面,实现连续深度、各向同性的三维可视化。

cs.CV

查看原文摘要

Reflectance confocal microscopy (RCM) provides noninvasive, cellular-resolution "optical biopsies" of human skin in vivo by acquiring en-face images at successive depths, forming a sparse z-stack. Due to optical limitations, these stacks are anisotropic 3D volumes with lateral resolution (0.5 $μ$m) $\sim$6 times higher compared to axial resolution, which is defined by the optical sectioning (3 $μ$m), limiting the interpretation of tissue. Our goal is to provide continuous-depth visualization by interpolating intermediate sections and making the 3D volume isotropic. Such a representation permits arbitrary-direction sectioning, including histopathology-like cross-sectional examination, without requiring per-patient optimization. To that end, we introduce the first RCM-specific novel-view synthesis (NVS) approach, CD-RCM, a feedforward model that predicts realistic, unseen depths from sparsely sampled RCM stacks. Classical neural rendering methods focus on reconstruction from surface-level multi-view observations. In contrast to surface-level camera views, RCM can acquire optically sectioned en-face images of tissue beyond the surface up to 200 $μ$m. However, during visualization of the RCM stacks, observations of the shallower sections (towards the surface) obscure the deeper ones. This unique axial imaging geometry and layer-dependent anatomical organization motivated our development of a tailored architectural and training framework that explicitly accounts for RCM's depth-resolved, occlusive imaging physics. Experiments demonstrate that CD-RCM achieves high-fidelity novel-view synthesis with sub-second inference time.