跳到正文
研踪PaperTrail

YOUR RESEARCH, IN SIGHT

让下一篇重要论文,不再错过。

覆盖计算机全学科,以 AI 为快捷入口。关注方向、作者和关键词,把发现变成持续的研究积累。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+0新增论文
+0其中 AI 相关
+1已有论文修订
+100新增 AI 导读

arXiv 最近完成扫描:2026-11-08 23:55 · 全站最近入库:2026-11-08 06:02各信源进度 →

统计口径与数据新鲜度

统计 2026-11-08 00:27 — 2026-11-09 00:27(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-08 23:55最近发现新增版本:2026-11-08 06:02库内论文最新更新时间:2026-11-06 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

17,100 已收录论文14,661 AI 相关4,057 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-08 23:54(北京时间)
新论文 · v1arXiv:2610.34600

FlexiMIND: Combined Pretrained Vision Features and Local Structure for Training-Free Deformable Medical Image Registration

Mojtaba Safari, Mingzhe Hu, Shansong Wang, Suyang Xi, Joshua Lorenz, Sean Pitroda, Aytekin Oto, Ralph R. Weichselbaum 等 9 位作者

原文摘要

Objective. Deformable image registration remains challenging because corresponding anatomy may exhibit different intensity relationships. Hand-crafted modality-robust descriptors such as Modality-Independent Neighborhood Descriptor with Self-Similarity Context (MIND-SSC) and features from pretrained vision encoders provide distinct representations for correspondence estimation, but how they should be combined remains unclear. We investigate whether tighter integration improves registration over a sequential, scale-separated design. Approach. We introduce FlexiMIND, a training-free and label-free two-stage framework in which frozen FlexiCT-2D encoder features establish contextual correspondence and MIND-SSC refines the deformation within ConvexAdam. Five alternative feature-coupling strategies were evaluated under a protocol across CT-CT (DIR-Lab 4DCT 4DCT, 10 cases), MR-MR (ACDC, 50 patients), and MR-CT (Learn2Reg Abdomen MR-CT, 8 pairs) registration. Performance was assessed using target registration error (TRE), Dice similarity coefficient (Dice), SDlogJ, and local folding. Main results. FlexiMIND achieved a TRE of 1.27 mm on DIR-Lab 4DCT, a DSC of 0.807 on ACDC, and an organ-averaged DSC of 0.825 on Abdomen MR-CT. Across 15 coupling-strategy dataset comparisons, only four outperformed the reference method, with a maximum absolute improvement of 0.0043 in Dice, whereas degradation reached 20.6 % in TRE and 37.9 % in Dice. Changes in registration accuracy were closely associated with changes in deformation-field regularity, and strategies that better preserved regularity generally remained closest to the reference performance. Landmark-level analysis showed that the pretrained encoder stage primarily reduced large correspondence errors rather than uniformly improving local precision. Code is available upon acceptance at https://github.com/mosaf/FlexiMIND.

cs.CV