跳到正文
研踪PaperTrail

YOUR RESEARCH, IN SIGHT

让下一篇重要论文,不再错过。

覆盖计算机全学科,以 AI 为快捷入口。关注方向、作者和关键词,把发现变成持续的研究积累。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+1151新增论文
+896其中 AI 相关
+86已有论文修订
+100新增 AI 导读

arXiv 最近完成扫描:2026-11-06 21:37 · 全站最近入库:2026-11-06 13:12各信源进度 →

统计口径与数据新鲜度

统计 2026-11-05 21:47 — 2026-11-06 21:47(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-06 21:37最近发现新增版本:2026-11-06 13:12库内论文最新更新时间:2026-11-06 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

17,100 已收录论文14,661 AI 相关4,055 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-06 21:31(北京时间)
版本更新 · v3arXiv:2605.24609

Deep learning-based self-supervised detection and localization of magnetic resonance imaging anomalies in artificial intelligence-supported radiotherapy workflows

Mustafa Kadhim, Viktor Rogowski, Emilia Persson, Camila Gonzalez, André Haraldsson, Sofie Ceberg, Mikael Nilsson, Malin Kügele 等 10 位作者

Artificial intelligence is increasingly integrated into radiotherapy workflows, yet it remains vulnerable to out-of-distribution image data that can introduce unexpected behavior in clinical tasks. Deep learning (DL)-based anomaly detection for pelvic magnetic resonance imaging (MRI) remains limited and transparent evaluation for full automation is lacking. This study aimed to develop two self-supervised anomaly-detection framework variations in radiotherapy for pelvic and brain MRI.A two-stage self-supervised DL-framework was trained separately for pelvic and brain MRI utilizing three public datasets. The first stage compressed normal image data into discrete representations, and a second stage modeled the representation distribution. Anomaly-evidence was obtained by combining perceptual image differences with token-surprisal scores via negative log-likelihood estimation. Automated detection was evaluated for two anatomical cohorts: pelvis, encompassing both synthetic global anomalies and real clinical anomalies, and brain, comprising clinically annotated anomalies. Performance was assessed using sensitivity, specificity, and area under the receiver operating characteristic curve (AUC). For each cohort, a subset of normal images was reserved for analysis. Promising exploratory performance across evaluation cohorts was obtained. AUCs were 0.97 (95% CI 0.96-0.99) for synthetic pelvic anomalies, 0.95 (95% CI 0.90-1.00) for clinical pelvic anomalies, and 0.81 (95% CI 0.74-0.87) for brain anomalies. Qualitative heatmap analysis showed spatial agreement between detected anomalies and reference annotations. The framework variations showed promising anomaly detection performance across pelvic and brain MRI, supporting its potential for automated MRI quality control in radiotherapy. Heatmap-based visualization further improved interpretability by spatially localizing detected anomalies.

尚无 AI 解读,展示原文摘要

physics.med-ph · cs.AI · cs.CV
arXiv ↗PDF ↗