跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+2152新增论文
+1726其中 AI 相关
+261已有论文修订
+25新增 AI 导读

arXiv 最近完成扫描:2026-11-24 11:47 · 全站最近入库:2026-11-24 14:50各信源进度 →

统计口径与数据新鲜度

统计 2026-11-23 19:03 — 2026-11-24 19:03(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-24 11:47最近发现新增版本:2026-11-24 14:50库内论文最新更新时间:2026-11-24 00:15

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

31,737 已收录论文26,241 AI 相关9,982 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 2 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-24 11:40(北京时间)
新论文 · v1arXiv:2611.25777

Hindsight Self-Distillation: Teaching Robots to Act from the Present

Haisen He, Yechi Liu, Tianle Shi, Haoyun Liu, Chuanzhang Meng, Tiancai Jiao, Yifan Bai, Xinyuan Chang 等 10 位作者

原文摘要

A robot must choose an action before it can see the outcome. In a recorded demonstration, later camera frames show what happened after the robot moved. Hindsight Self-Distillation (HSD) uses these later frames to teach a policy what to extract from current images. During training, a teacher sees both the current and later frames, while a student sees the current frames. They share a visual encoder and an action predictor. Each branch summarizes its images with a small set of feature vectors. These visual summaries supply all visual input to the action predictor. The teacher learns from demonstrated actions. For each noisy action sequence, the student learns from either the demonstration or the teacher's denoising prediction. It also learns to match the teacher's visual summaries. We analyze which aspects of the teacher's predictions the student can recover from its inputs. At deployment, the student encodes the current images once and reuses its summaries at every denoising step. HSD achieves average success rates of 98.50\% on LIBERO and 92.31\% on RoboTwin 2.0.

cs.RO

新论文 · v1arXiv:2611.06471

A 3D foundation model unifying CT interpretation and segmentation

Yulu Xie, Zilong Li, Shen Xu, Yifan Bai, Liuhong Shi, Jiao Chen, Xianglei Kong, Wenchao Zhu 等 17 位作者

原文摘要

Radiologists interpret computed tomography (CT) scans by jointly determining what a finding represents and where it lies in three-dimensional (3D) anatomy. However, CT models have treated CT interpretation and 3D segmentation as separate tasks, leaving textual findings spatially unverifiable and overlooking potential synergy between clinical understanding and spatial perception. Here we present HoloCT, a generalist 3D foundation model unifying CT interpretation and voxel-level segmentation by jointly modelling whole-volume context and fine-grained anatomical detail, providing 3D masks as evidence. We curated HoloDATA, comprising 195,921 CT scans from 73 public datasets and six clinical cohorts, with 6.2 million instruction dialogues and 2.8 million CT-mask pairs. Across 346 tasks spanning segmentation, lesion screening, visual question answering, and report generation on 61 internal and 12 external datasets, HoloCT outperformed specialist and foundation models. In multicentre validation across 11,455 clinical CT scans from five hospitals, HoloCT outperformed competing models in lesion segmentation and report generation by 18.2 and 15.3 points. It also achieved 85.1% mean accuracy in screening thyroid tumours and colon lesions, exceeding all four participating radiologists in a retrospective reader study. Further analyses revealed bidirectional semantic-spatial synergy: language-guided segmentation delineated unseen anatomical structures and lesions as well as diffuse free-text findings, outperforming the leading approach by 22.1 points, whereas prompting the model to generate corresponding 3D masks alongside its textual outputs significantly improved interpretation performance. HoloCT shows that clinical understanding and spatial perception can be learned together within a single foundation model and offers a path towards more accurate and reliable CT analysis.

cs.CV