跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+1680新增论文
+1333其中 AI 相关
+187已有论文修订
+59新增 AI 导读

arXiv 最近完成扫描:2026-11-18 04:28 · 全站最近入库:2026-11-17 23:35各信源进度 →

统计口径与数据新鲜度

统计 2026-11-17 11:00 — 2026-11-18 11:00(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-18 04:28最近发现新增版本:2026-11-17 23:35库内论文最新更新时间:2026-11-17 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

25,786 已收录论文21,491 AI 相关7,725 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-18 04:27(北京时间)
版本更新 · v3arXiv:2510.01712

ActiNet:基于自监督深度学习的手腕加速度计活动强度分类开源工具

ActiNet: An Open-Source Tool for Activity Intensity Classification of Wrist-Worn Accelerometry Using Self-Supervised Deep Learning

Aidan Acquah, Shing Chan, Aiden Doherty

AI 速读 基于摘要

作者提出并评估了开源工具ActiNet,结合自监督ResNet与HMM平滑,用于手腕加速度计的活动强度分类,性能优于随机森林基线。

cs.LG

查看原文摘要

The use of accurate and reliable open-source human activity recognition (HAR) models on passively collected wrist-accelerometer data is essential in large-scale epidemiological studies that investigate the association between physical activity and health outcomes. While self-supervised learning has generated considerable excitement in improving HAR, the extent to which these models, coupled with hidden Markov models (HMMs), would make a tangible improvement to classification performance and the effect this may have on the predicted daily activity intensity compositions is unknown. Using up to 24 hours of wrist-worn accelerometer data from 151 CAPTURE-24 participants (aged 18-91, mean age 42, 66% female), we trained the ActiNet model, consisting of HARNet, a self-supervised, 18-layer, modified ResNet-V2 model, followed by hidden Markov model (HMM) smoothing, to classify labels of activity intensity. The performance of this model, evaluated using 5-fold stratified group cross-validation, was then compared to a baseline random forest (RF) + HMM, established in existing literature. Differences in performance and classification outputs were compared with different subgroups of age and sex within the CAPTURE-24 population. The ActiNet model was able to distinguish labels of activity intensity with a mean macro F1 score of 0.80 and a mean Cohen's kappa score of 0.85. This exceeded the performance of the RF + HMM, trained and validated on the same dataset, with mean scores of 0.76 and 0.80, respectively. The improvements in performance were consistent across subgroups of age and sex. These findings encourage the use of ActiNet for the extraction of activity intensity labels from wrist-accelerometer data in future epidemiological studies.