跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+1356新增论文
+1080其中 AI 相关
+186已有论文修订
+25新增 AI 导读

arXiv 最近完成扫描:2026-11-24 11:47 · 全站最近入库:2026-11-24 11:46各信源进度 →

统计口径与数据新鲜度

统计 2026-11-23 12:04 — 2026-11-24 12:04(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-24 11:47最近发现新增版本:2026-11-24 11:46库内论文最新更新时间:2026-11-22 13:30

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

30,514 已收录论文25,261 AI 相关9,506 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 2 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-24 11:40(北京时间)
版本更新 · v2arXiv:2605.31094

Redefining Instance Matching: A Unified Framework for Part-Aware Matching in Panoptic Segmentation Evaluation

Erik Großkopf, Soumya Snigdha Kundu, Hendrik Möller, Nicolas Münster, Mehdi Astaraki, Paula Tamara Buzduga, Kerstin Ritter, Benedikt Wiestler 等 12 位作者

原文摘要

The Panoptic Quality metric is the standard for jointly evaluating instance and semantic segmentation. Its original definition matches predicted and ground truth segments only if their intersection over union exceeds 0.5, a threshold that guarantees a One-to-One matching that is both optimal and unique. Below this threshold, the uniqueness guarantee is lost and multiple matching strategies emerge in a poorly explored problem space. We systematically elucidate this space by recasting segment matching as a constrained bipartite assignment problem. Independently bounding the prediction- and ground-truth-side degrees yields four matching strategies: One-to-One, Many-to-One, One-to-Many, and Many-to-Many. We show that the first three yield interpretable instance-level assignments, whereas Many-to-Many entangles over- and under-segmentation and admits no consistent attribution of errors. These strategies become relevant when instances are fragmented, adjacent objects are difficult to delineate, or annotations are noisy. Central to our framework is a vertex-based accounting of TP, FP, and FN, anchored to ground truth and predicted segments rather than to matching edges. We further show that the framework extends naturally to part-aware panoptic segmentation and illustrate this extension conceptually on biomedical examples. Across configurable case studies we report how different combinations of thresholds and matching strategies behave in practice.

cs.CV · cs.AI

新论文 · v1arXiv:2611.21412

Flexible Multi-Stack Super-Resolution of Clinical Brain MRI Using Hetero-Orientation Variational Encoding: Expert Reader Evaluation in a Nigerian Cohort

Kabir Hamzah Muhammad, Lorena Garcia-Foncillas Macias, Soumya Snigdha Kundu, Emily Guilhem, Jon Cleary, Amal Saleh Nour, Yodit Abraham Yaynishet, Chinasa Kalaiwo 等 13 位作者

原文摘要

High-resolution brain MRI is important for neuroradiological assessment, yet routine clinical protocols often rely on fast, anisotropic 2D acquisitions, particularly in resource-constrained settings. These acquisitions may differ in orientation, alignment and anatomical coverage, resulting in partially overlapping image stacks. Existing learning-based super-resolution methods typically rely on single, under-constrained inputs or fixed multi-stack configurations with idealised acquisition geometry. We introduce MS-HVED, a sequence-agnostic framework for flexible multi-stack brain MRI super-resolution. Available axial, coronal and sagittal stacks are independently encoded into multi-scale Gaussian posteriors and fused using a field-of-view-aware Product-of-Gaussians formulation that limits contributions from unsupported regions. Physics-informed domain randomisation simulates heterogeneous clinical acquisition conditions, including obliqueness, partial coverage and imaging artefacts. MS-HVED achieved competitive or superior reconstruction fidelity across synthetic benchmarks and improved downstream tissue segmentation relative to low-resolution inputs. To assess generalisation beyond the training cohorts, we performed external clinical validation on 30 routine brain MRI examinations from a Nigerian cohort, representing an under-represented population in medical imaging research. These examinations formed the largest component of a blinded reader study involving 44 real cases and seven expert neuroradiologists. In the Nigerian cohort, MS-HVED was preferred over the supervised baseline for overall image quality in 187 of 210 paired assessments. Across all clinical cohorts, MS-HVED achieved higher overall-quality scores with all available inputs (5.93 vs. 4.49, p<.001), with the preference persisting when axial or coronal inputs were omitted (p<.001). Code at github.com/cai4cai/ms-hved

cs.CV