跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+1084新增论文
+883其中 AI 相关
+130已有论文修订
+94新增 AI 导读

arXiv 最近完成扫描:2026-11-18 04:28 · 全站最近入库:2026-11-18 19:45各信源进度 →

统计口径与数据新鲜度

统计 2026-11-18 03:41 — 2026-11-19 03:41(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-18 04:28最近发现新增版本:2026-11-18 19:45库内论文最新更新时间:2026-11-18 08:00

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

26,870 已收录论文22,374 AI 相关8,156 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-18 04:27(北京时间)
版本更新 · v2arXiv:2605.17620

SynVA: A Modular Toolkit for Vessel Generation and Aneurysm Editing

Marten J. Finck, Niklas C. Koser, Sarker M. Mahfuz, Tameem Jahangir, Jon E. Wilhelm, Daniel Behme, Naomi Larsen, Wojtek Palubicki 等 10 位作者

原文摘要

Intracranial aneurysms (IAs), characterized by unpredictable growth and risk of rupture, are a major cause of stroke and can lead to life-threatening hemorrhages with high mortality and long-term disability. With aging populations, the incidence and overall burden of cerebrovascular diseases are expected to increase, highlighting the need for scalable approaches to analyze complex medical data and improve population-level understanding of these conditions. While digital twins and deep learning offer promising avenues for improving diagnosis, prognosis, and treatment, their effectiveness is limited by the scarcity of large-scale, high-quality medical data and corresponding labels. We present Synthetic VAsculature (SynVA), a modular toolkit for vascular mesh generation and anatomically consistent aneurysm synthesis. SynVA combines novel flow-matching-based methods for generating healthy vessel meshes with learning-based approaches for anatomy-conditioned aneurysm mesh generation; it computes aneurysms from pre-existing vascular geometries rather than generating them in isolation. In addition, we introduce the SynVA procedural model for vascular and aneurysm synthesis based solely on physiological principles and statistical priors, which enables the generation of large-scale datasets. To this end, we release a dataset of 50,000 fully labeled mesh samples for a variety of downstream vision tasks. Extensive quantitative and qualitative evaluations show that SynVA generates realistic vessel geometries and anatomically plausible aneurysms, with only minor trade-offs between expert-perceived realism and similarity to real aneurysms. Moreover, pretraining on SynVA data improves point-cloud segmentation and morphological parameter estimation on real data. Code will be released upon acceptance.

cs.CV · cs.AI · cs.LG