跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+0新增论文
+0其中 AI 相关
+0已有论文修订
+0新增 AI 导读

arXiv 最近完成扫描:2026-11-28 09:33 · 全站最近入库:2026-11-26 12:29各信源进度 →

统计口径与数据新鲜度

统计 2026-11-27 11:49 — 2026-11-28 11:49(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-28 09:33最近发现新增版本:2026-11-26 12:29库内论文最新更新时间:2026-11-26 08:00

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

34,433 已收录论文28,422 AI 相关10,935 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 2 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-28 09:30(北京时间)
新论文 · v1arXiv:2611.33425

Anatomy-Aware Pseudo-Labels and Homotopy-Annealed Hausdorff Supervision for Semi-Supervised Pancreas Segmentation

Alireza Kheyrkhah, Amir Hossein Saleknia, Reza Azad, Sina Houshmand, Dorit Merhof, Ulas Bagci, Alaa Sulaiman

原文摘要

Confidence-gated co-training assumes that pseudo-label errors are uncertain and concentrated at organ boundaries. We argue that for pancreas CT, where the target organ is a single connected structure and detached fragments are anatomically implausible, the dominant failures arise at three levels: where the organ is, what its boundary should look like, and how a correct boundary is penalized. Anatomical Rectification relabels implausible fragments of a teacher prediction as confident background, without adding any loss or parameter; an audit confirms that its rejections are overwhelmingly detached hallucinations and that thin, tail-like slices are not eroded. Boundary Grafting transplants labelled surface regions with their annotation into unlabeled volumes, replacing unreliable boundary pseudo-labels with ground truth. The residual error is coherent surface displacement, weakly penalized by permutation-invariant Dice and cross-entropy losses. Homotopy-Annealed Hausdorff (HAH) supervision anneals a distance-weighted penalty from an annotation-anchored objective that is convex in the prediction to a Hausdorff surrogate, admitting the prediction-dependent distance term only after the predicted surface becomes reliable. On NIH pancreas CT, under the standard semi-supervised split, the full method reaches 84.60% Dice and 4.97 voxels 95HD, improving all four metrics over compared methods; on MSD Task07, 78.90% Dice and 4.19 voxels 95HD. We further contribute PanTS-SSL, a semi-supervised evaluation protocol derived from the public 9,901-case PanTS corpus, with a curated 1,015-volume main pool, labelled tiers of 50, 100 and 250 volumes, an 80-case tumor track, shift probes for acquisition and anatomy change, and a fixed 901-volume test set. On it, the method exceeds the co-training baseline at 100 labels, scales to 85.29% Dice at 250 labels, and reaches 85.50% Dice at 100 labels with HAH.

cs.CV

新论文 · v1arXiv:2611.13425

Prompt2Echo (P2Echo): Text-Prompted Multi-View Echocardiography Segmentation with One Model

Moein Heidari, Alvin Kimbowa, Mahdi Tabatabaei, Afshin Bozorgpour, Sina Ghorbani Kolahi, River Jiang, Wenjin Chen, David J. Foran 等 11 位作者

原文摘要

Automated segmentation in multi-view echocardiography is essential for comprehensive cardiac assessment, yet remains challenging due to substantial anatomical and appearance variability across standard acoustic windows. In this paper, we present P2Echo, a unified framework capable of segmenting diverse cardiac structures across multiple standard echocardiographic views using a single model controlled by structured view-aware text prompts. Unlike recent foundation model adaptations that rely on implicit latent priors, P2Echo explicitly conditions the segmentation process via a novel Dynamic Image-Text Alignment (DyITA) module. DyITA integrates a differentiable routing mechanism and token differential operators to dynamically modulate decoder features according to the requested view and target structure. This allows the network to adaptively switch its processing pathways for different views without architectural changes. Extensive experiments on a large-scale internal dataset (seen during training) and held-out evaluation on three external datasets demonstrate that P2Echo matches or exceeds both view-specific specialists and state-of-the-art universal models at a fraction of their computational cost, offering an efficient, controllable solution for multi-plane cardiac analysis. Code is available at: https://github.com/moeinheidari7829/P2Echo.

cs.CV