跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+1299新增论文
+1041其中 AI 相关
+170已有论文修订
+1新增 AI 导读

arXiv 最近完成扫描:2026-11-26 05:14 · 全站最近入库:2026-11-25 13:23各信源进度 →

统计口径与数据新鲜度

统计 2026-11-25 05:55 — 2026-11-26 05:55(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-26 05:14最近发现新增版本:2026-11-25 13:23库内论文最新更新时间:2026-11-25 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

33,231 已收录论文27,442 AI 相关10,485 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 2 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-26 05:12(北京时间)
新论文 · v1arXiv:2611.28915

Which Model Belongs in the Loop? Evaluating Fitness Functions for Network Topology Optimization with a Quality-Diversity Algorithm

Paul Bannmüller, Olayiwola Arowolo, Jochen Stiasny, Jochen Cremer

原文摘要

Network topology optimization (NTO) can reduce redispatch cost by rerouting power flows in transmission systems. To approach NTO, a complex combinatorial problem, gradient-free optimization algorithms that leverage diversity have shown promising results. These algorithms rely on frequent evaluations of candidate topologies by fitness functions. Recent work has shown that fast DC power flow-based fitness functions can serve this purpose. However, DC power flow fitness functions can misjudge the cost and feasibility of topologies, potentially leading to wrong operational decisions. Understanding the impact of fitness function accuracy on optimization performance is therefore crucial. This study compares the optimization performance of four fitness functions based on DC and AC power flow and on DC and AC optimal power flow. Furthermore, we propose a ranking-based metric to estimate the optimization performance of a fitness function on a curated dataset. Case studies cover the IEEE 118-bus case with 50 congested operating points and a 793-bus case for validation. Results show that optimal power flow-based fitness functions perform better in the optimization loop than power flow-based ones. Additionally, the results indicate that the metric can predict the optimization performance order of the fitness functions, but only if the distribution shift between the curated dataset and the search path of the optimization is small.

cs.NE · eess.SY

版本更新 · v2arXiv:2607.16031

Revisiting data-driven dynamic security assessment with a tabular foundation model

Olayiwola Arowolo, Maosheng Yang, Jochen Cremer

原文摘要

Data-driven pre-fault dynamic security assessment (DSA) rapidly evaluates the dynamic risk of credible contingencies on a power system using machine learning (ML). Existing approaches face two limitations. First, they require a large labelled database for training, with a separate model trained, tuned, and maintained for each contingency in a potentially long list of credible contingencies. Second, the trained models generalize poorly to unseen contingencies. This work addresses these limitations by using a tabular foundation model (TFM) that assesses stability through in-context learning, and requires no retraining or hyperparameter optimization. We use a single TFM to assess many contingencies at once, removing the need to train one classifier per contingency. We also characterize when using electrical distance coordinates (EDC) as continuous features enables the TFM to generalize to unseen contingencies and when it does not, showing how a few labelled samples can reliably improve generalization. Through comprehensive case studies on the IEEE 68-bus system, we show that a single TFM attains an average Macro F1 score of about 90\% with only 120 labelled samples per contingency, outperforming both classical ML and deep learning baselines, without any model retraining or hyperparameter tuning. For held-out contingencies, we show that using just 10 labelled samples of the new contingency with a modified EDC encoding matches the balanced accuracy of the best achievable transfer learning oracle model, which requires fully labelled data and is not deployable in practice. Overall, this initial study paves the way for developing and deploying foundation models for power system operations, with possible applications across multiple operational tasks.

cs.LG · cs.AI