跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+1494新增论文
+1201其中 AI 相关
+180已有论文修订
+0新增 AI 导读

arXiv 最近完成扫描:2026-11-25 17:40 · 全站最近入库:2026-11-25 13:23各信源进度 →

统计口径与数据新鲜度

统计 2026-11-24 18:40 — 2026-11-25 18:40(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-25 17:40最近发现新增版本:2026-11-25 13:23库内论文最新更新时间:2026-11-25 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

33,231 已收录论文27,442 AI 相关10,485 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 2 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-25 17:38(北京时间)
版本更新 · v2arXiv:2506.14303

orGAN: A Synthetic Data Augmentation Pipeline for Simultaneous Generation of Surgical Images and Ground Truth Labels

Niran Nataraj, Maina Sogabe, Kenji Kawashima

原文摘要

Deep learning for surgical image analysis is constrained by limited data diversity, ethical restrictions, high acquisition costs, and the scarcity of accurately annotated bleeding datasets, making reliable bleeding localization particularly challenging. To address these limitations, we propose orGAN, a modular framework that generates realistic, fully annotated synthetic surgical bleeding images together with recoverable point-level supervision. To overcome the ethical and cost barriers of real surgical data, the pipeline is trained on silicone-based mimicking organs that reproduce tissue properties, using an enhanced StyleGAN3 generator coupled with Relational Positional Learning to embed bleeding coordinates, a Surgical Label Detection Algorithm to recover coordinate and mask labels, and a fine-tuned LaMa inpainting network to restore clean image-label pairs. To compensate for scarce annotations, Bleeding Alert Map (BAM) localization models are trained on a blend of synthetic and mimicking-organ images. The enhanced StyleGAN3 attains an Inception Score of 2.24, and the inpainting network preserves realism at a mean SSIM of 0.98. The blended model outperforms both single-source baselines, reaching a Dice coefficient of 0.635 on paired bleeding frames. With a stronger Pix2PixHD backbone, Dice rises to 0.893 with a centroid error of 6.3 pixels. On real Hamlyn surgical video, the blended model achieves a frame-level accuracy of 0.858 and a bleeding-frame detection rate of 0.998 on Hamlyn 2, where all 500 frames were annotated as bleeding-positive. These results show that combining realistic synthetic images with mimicking-organ data is an effective, ethical, and economical strategy for developing surgical AI under limited annotated data.

eess.IV · cs.AI · cs.CV

版本更新 · v3arXiv:2611.13971

TransGHOST: Real-Time, Synthesis-Free Reconstruction of Instrument-Occluded Regions in Ophthalmic Microsurgery

Niran Nataraj, Maina Sogabe, Norihiko Ito, Kenji Kawashima

原文摘要

Intraoperative scene perception in ophthalmic microsurgery is limited by instrument occlusion: when a tool enters the high-magnification field, it conceals tissue from both the surgeon and the perception components of robot-assisted systems that process the video. Generative inpainting can remove the occluder but replaces the missing image content with synthesis, which is unsuitable when visual provenance matters. Many video inpainters also depend on future frames and cannot operate online. We present TransGHOST, a causal reference-guided reconstruction pipeline whose non-generative safe mode operates in real time. Every restored value is obtained by resampling a recorded frame using geometric transforms fitted only to visible regions. The system provides per-pixel confidence and provenance and marks unsupported pixels as abstentions. We evaluate TransGHOST on a new veterinary clinical corpus of canine cataract surgery with pixel-level instrument and anatomy labels. Only the occluded region is scored, and each scoring target is verified to differ from the reference supplied to the system. Safe mode reaches 31.89 dB masked PSNR and 0.915 masked SSIM at 51.7 ms median and 85.5 ms 95th-percentile latency. On a pre-declared held-out cohort using instrument cutouts excluded from segmentation training, it reaches 29.83 dB masked PSNR, while matched-mask evaluation on validation shows a 3.45 dB advantage over LaMa. Region-aware reference selection improves masked PSNR by 3.60 dB over recency when candidate references can themselves be occluded. Reference-age analysis further defines the operating interval for the brief, repeated occlusions targeted by TransGHOST.

eess.IV · cs.AI · cs.CV · cs.RO