跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+1202新增论文
+980其中 AI 相关
+155已有论文修订
+1新增 AI 导读

arXiv 最近完成扫描:2026-11-26 17:41 · 全站最近入库:2026-11-26 12:29各信源进度 →

统计口径与数据新鲜度

统计 2026-11-25 22:30 — 2026-11-26 22:30(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-26 17:41最近发现新增版本:2026-11-26 12:29库内论文最新更新时间:2026-11-26 08:00

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

34,433 已收录论文28,422 AI 相关10,935 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-26 17:39(北京时间)
新论文 · v1arXiv:2611.32823

Reliable and grounded reporting of any computed tomography scan with FORA

Sezgin Er, Utku Turkbey, Alperen Gur, Omer Faruk Durugol, Suprosanna Shit, Murong Xu, Julia Wolleb, Jiayi Wang 等 24 位作者

原文摘要

Artificial intelligence systems for computed tomography (CT) remain largely restricted to specific anatomical regions, examination types or predefined abnormalities, limiting their ability to provide comprehensive and spatially grounded interpretations. Here we present FORA, a general-purpose CT model that recognizes and spatially localizes 1,028 hierarchically organized radiological concepts and generates reports across the 28 CT protocols represented in our cohort. Trained on 304,962 routine CT examinations supervised by their accompanying reports, FORA learns to localize abnormalities without manually annotated lesions. Its architecture combines multiple-instance learning with an interpretable concept bottleneck that connects spatial evidence, radiological findings and report generation. We first developed and benchmarked the architecture on chest radiographs, achieving state-of-the-art performance, before training a separate model on three-dimensional CT examinations. On 36,619 held-out CT examinations, FORA achieved a macro area under the receiver operating characteristic curve (AUROC) of 0.918 for radiological concept recognition, exceeding the strongest of 18 existing CT models by 0.21. FORA also ranked first on three public benchmarks, outperforming Merlin on its own test set without training on that institution's data (AUROC 0.907 versus 0.826). On independent localization benchmarks for pulmonary emboli, renal masses and rib fractures, FORA's strongest spatial evidence fell within annotated lesions at rates up to 348 times greater than chance. FORA achieved more than threefold higher macro-averaged finding recall than the strongest existing report generator. These results show that a single model can combine broad abnormality recognition, spatial localization and report generation across 12 CT examination types, using routine reports without lesion-level supervision.

cs.CV · cs.AI