跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2605.00645 · v2

From Prediction to Practice: A Task-Aware Evaluation Framework for Blood Glucose Forecasting

首次提交 2026-05-01 21:26
版本更新 2026-11-11 02:29
雷达观测 2026-11-13 11:12
arXiv ↗PDF ↗

摘要

Clinical time-series forecasting is increasingly studied for decision support, yet standard aggregate metrics can obscure whether a model is actually useful for the task it is meant to serve. In safety-critical settings, low average error can coexist with dangerous failures in exactly the high-risk regimes that matter most. We present a task-aware evaluation framework for blood glucose forecasting built around two downstream uses: hypoglycemia early warning and insulin dosing decision support. For early warning, we evaluate on real data from three clinical cohorts using event-level recall and false alarms per patient-day, metrics that reflect operational alarm burden rather than aggregate accuracy. We show that models appearing acceptable overall, with recall above 0.9 on the full test set, can fail badly in the post-bolus slice, where insulin-on-board is elevated and missed warnings carry the greatest clinical consequences. Standard forecasting evaluation, however, does not test whether a model can reason about the effects of actions, a requirement for supporting insulin dosing decisions. We therefore add a second, interventional arm using the FDA-accepted UVA/Padova simulator, where we evaluate whether forecasters can predict glucose responses to altered insulin plans in paired factual/counterfactual scenarios. We show that models that look strong on real-data forecasting often fail to predict the direction, magnitude, or ranking of intervention effects, and choose poor insulin doses when evaluated under a clinically motivated cost. Taken together, the two arms reveal a consistent gap between forecasting accuracy and task-relevant usefulness. We release the benchmark, the standardized preprocessing pipeline for public cohorts, and the simulator-based interventional dataset as a reproducible toolkit.

作者备注:Accepted to ML4H 2026 (Proceedings Track). This revision corrects hypoglycemia alarm matching, updates the advance-warning analysis and its claims, and replaces the simulator evaluation with four-hour Control-IQ experiments. Code and simulated data are publicly available

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

本站首次收录为 v2,暂无更早版本可对照。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v2 · 2026-11-11 02:29 · 最新观测版本

From Prediction to Practice: A Task-Aware Evaluation Framework for Blood Glucose Forecasting

Clinical time-series forecasting is increasingly studied for decision support, yet standard aggregate metrics can obscure whether a model is actually useful for the task it is meant to serve. In safety-critical settings, low average error can coexist with dangerous failures in exactly the high-risk regimes that matter most. We present a task-aware evaluation framework for blood glucose forecasting built around two downstream uses: hypoglycemia early warning and insulin dosing decision support. For early warning, we evaluate on real data from three clinical cohorts using event-level recall and false alarms per patient-day, metrics that reflect operational alarm burden rather than aggregate accuracy. We show that models appearing acceptable overall, with recall above 0.9 on the full test set, can fail badly in the post-bolus slice, where insulin-on-board is elevated and missed warnings carry the greatest clinical consequences. Standard forecasting evaluation, however, does not test whether a model can reason about the effects of actions, a requirement for supporting insulin dosing decisions. We therefore add a second, interventional arm using the FDA-accepted UVA/Padova simulator, where we evaluate whether forecasters can predict glucose responses to altered insulin plans in paired factual/counterfactual scenarios. We show that models that look strong on real-data forecasting often fail to predict the direction, magnitude, or ranking of intervention effects, and choose poor insulin doses when evaluated under a clinically motivated cost. Taken together, the two arms reveal a consistent gap between forecasting accuracy and task-relevant usefulness. We release the benchmark, the standardized preprocessing pipeline for public cohorts, and the simulator-based interventional dataset as a reproducible toolkit.

查看此版本解读 →查看此版本原文 ↗