← 研踪 PaperTrailarXiv:2607.20943 · v2
An Analytically Trained Variational Quantum Circuit using the Output Probability Distribution of Quantum Phase Estimation on NISQ Hardware
首次提交 2026-07-23 13:52
版本更新 2026-11-20 14:37
雷达观测 2026-11-24 11:46
摘要
Quantum Phase Estimation (QPE) is the standard algorithm for molecular ground-state energy estimation and often serves as a subroutine in larger quantum algorithms, but its deep circuits make it impractical on current noisy hardware. A previous variational approach replaces the QPE subroutine with a shallow Variational Quantum Circuit (VQC) trained to reproduce the QPE measurement distribution, but generates the training target by classically simulating the full QPE circuit, which is prohibitive for molecules. We reformulate this idea, computing the training target analytically from the Dirichlet kernel, using only a reference energy, the number of ancilla qubits and the evolution time, so the controlled-unitary and inverse-QFT operations of QPE are never simulated. Using H, we select the VQC stepwise by comparing its IBM Quantum hardware output with the target using four metrics. We first choose the entangler (linear or full) and number of layers of an -- ansatz, with and without dynamical decoupling (DD). As DD degraded performance with depth, we then choose, without DD, the ansatz (-- or -) and the training simulator (ideal or noisy). The configuration fixed on H, a single-layer linear-entangler - ansatz trained on the ideal simulator, is validated on LiH, HO, BeH, NH, CH, O and N, recovering the dominant QPE bitstring on hardware with errors within chemical accuracy ( Ha) for all eight molecules at the chosen evolution times. We also analyze the hardware side lobes of both ansätze, and a noise analysis of the selected ansatz at 8 and 64 layers examines how DD performs with depth. As training requires a known reference energy, the surrogate is not meant for standalone energy estimation, but can replace the QPE subroutine where a larger algorithm uses only its measurement outcome.
作者备注:34 pages, 14 figures (including Supplementary Material). v2: extended validation to LiH, H2O, BeH2, NH3, CH4, O2 and N2; revised title and abstract; theoretical background moved to Supplementary Material
观测到的版本
相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。
v2 · 2026-11-20 14:37 · 最新观测版本
An Analytically Trained Variational Quantum Circuit using the Output Probability Distribution of Quantum Phase Estimation on NISQ Hardware
Quantum Phase Estimation (QPE) is the standard algorithm for molecular ground-state energy estimation and often serves as a subroutine in larger quantum algorithms, but its deep circuits make it impractical on current noisy hardware. A previous variational approach replaces the QPE subroutine with a shallow Variational Quantum Circuit (VQC) trained to reproduce the QPE measurement distribution, but generates the training target by classically simulating the full QPE circuit, which is prohibitive for molecules. We reformulate this idea, computing the training target analytically from the Dirichlet kernel, using only a reference energy, the number of ancilla qubits and the evolution time, so the controlled-unitary and inverse-QFT operations of QPE are never simulated. Using H, we select the VQC stepwise by comparing its IBM Quantum hardware output with the target using four metrics. We first choose the entangler (linear or full) and number of layers of an -- ansatz, with and without dynamical decoupling (DD). As DD degraded performance with depth, we then choose, without DD, the ansatz (-- or -) and the training simulator (ideal or noisy). The configuration fixed on H, a single-layer linear-entangler - ansatz trained on the ideal simulator, is validated on LiH, HO, BeH, NH, CH, O and N, recovering the dominant QPE bitstring on hardware with errors within chemical accuracy ( Ha) for all eight molecules at the chosen evolution times. We also analyze the hardware side lobes of both ansätze, and a noise analysis of the selected ansatz at 8 and 64 layers examines how DD performs with depth. As training requires a known reference energy, the surrogate is not meant for standalone energy estimation, but can replace the QPE subroutine where a larger algorithm uses only its measurement outcome.
查看此版本解读 →查看此版本原文 ↗