跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2608.26739 · v2

Simulation-Based Evaluation of Residual DDPG-Augmented Computed Torque Control for a Cable-Driven Lower-Limb Rehabilitation Robot Model under Disturbances and Parametric Uncertainties

首次提交 2026-08-27 15:29
版本更新 2026-11-16 01:02
雷达观测 2026-11-17 17:12
arXiv ↗PDF ↗

摘要

Nominal computed torque control (CTC) relies on accurate inverse dynamics; parameter mismatch and disturbances can leave tracking error, while joint limits and unilateral cable forces constrain motion. This numerical study evaluates a bounded Deep Deterministic Policy Gradient (DDPG) residual correction around nominal CTC for a planar three-degree-of-freedom, three-cable lower-limb rehabilitation robot model. In four simulation cases, we examine tracking, joint limits, workspace, cable-Jacobian conditioning and inferred cable demands. In a representative combined uncertainty/disturbance case, Cartesian RMS error was 0.0221419 m with CTC and 0.0128462 m with residual DDPG-CTC (approximately 42% lower). On a different circular reference, the residual branch nevertheless increased joint-limit-violating channel samples from 44 to 101. Separate supplemental experiments analyze training variability and checkpoints, alternative compensators, reward/action sensitivity, independently varied parameters and disturbances, trajectory transfer, constrained cable-force allocation and force lag. These studies show both improvements and failures, including early terminations and force-capacity-dependent degradation. The verified original algebraic force-backprojection path and later bounded-force simulations are distinguished; numerical allocations do not establish physical pretension or motor performance. Simscape and MSC ADAMS checks are numerical cross-model consistency assessments. No hardware, hardware-in-the-loop or patient tests were performed, and no clinical efficacy or physical safety guarantee is claimed.

作者备注:51 pages, 36 figures, 26 tables. Substantially revised version with expanded numerical evaluations of training reproducibility, checkpoint selection, controller comparisons, cable-force constraints, uncertainty robustness, and trajectory transfer. Limitations and conclusions clarified

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

本站首次收录为 v2,暂无更早版本可对照。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v2 · 2026-11-16 01:02 · 最新观测版本

Simulation-Based Evaluation of Residual DDPG-Augmented Computed Torque Control for a Cable-Driven Lower-Limb Rehabilitation Robot Model under Disturbances and Parametric Uncertainties

Nominal computed torque control (CTC) relies on accurate inverse dynamics; parameter mismatch and disturbances can leave tracking error, while joint limits and unilateral cable forces constrain motion. This numerical study evaluates a bounded Deep Deterministic Policy Gradient (DDPG) residual correction around nominal CTC for a planar three-degree-of-freedom, three-cable lower-limb rehabilitation robot model. In four simulation cases, we examine tracking, joint limits, workspace, cable-Jacobian conditioning and inferred cable demands. In a representative combined uncertainty/disturbance case, Cartesian RMS error was 0.0221419 m with CTC and 0.0128462 m with residual DDPG-CTC (approximately 42% lower). On a different circular reference, the residual branch nevertheless increased joint-limit-violating channel samples from 44 to 101. Separate supplemental experiments analyze training variability and checkpoints, alternative compensators, reward/action sensitivity, independently varied parameters and disturbances, trajectory transfer, constrained cable-force allocation and force lag. These studies show both improvements and failures, including early terminations and force-capacity-dependent degradation. The verified original algebraic force-backprojection path and later bounded-force simulations are distinguished; numerical allocations do not establish physical pretension or motor performance. Simscape and MSC ADAMS checks are numerical cross-model consistency assessments. No hardware, hardware-in-the-loop or patient tests were performed, and no clinical efficacy or physical safety guarantee is claimed.

查看此版本解读 →查看此版本原文 ↗