跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2609.02402 · v2

A Physics-Consistent Benchmark for Contact-Rich Human-Robot Interaction in Assistive Care

首次提交 2026-09-02 18:14
版本更新 2026-11-19 20:17
雷达观测 2026-11-20 16:53
arXiv ↗PDF ↗

摘要

Conventional task-level evaluation asks whether a robot policy completes a specified action, but can miss failures that emerge only during physical human contact. This limitation is critical in contact-rich assistive tasks, where meaningful evaluation requires a physically responsive human, interaction-quality assessment beyond task success, and a leak-free observer-scorer protocol. We introduce a physics-consistent benchmark for contact-rich human-robot interaction, instantiated in robot-assisted bathing. The benchmark combines a deformable, passively responding human, physics-aware scores alongside task-level success, and a frozen vision-only / scorer-only evaluation protocol. To establish physical validity, region-wise simulated responses are calibrated against force-indentation measurements from Franka impedance pushes on a medical-care manikin. Under a frozen T1-T7 protocol with 140 runs per method, an LLM-augmented state machine (State Machine) achieves 72.9% task success but drops to 56.4% after correct-region and force-safety screening; VoxPoser produces lighter and more stable contact but completes only 27.9% of trials; and zero-shot pi0.5 achieves 0.7% task success with no correct-region or safety-gated successes. These results show that task completion alone does not imply physically valid contact and motivate physics-aware screening before deployment of contact-rich assistive robot policies.

作者备注:8 pages, 4 figures. submitted to the 2026 IEEE International Conference on Robotics and Biomimetics (ROBIO)

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

本站首次收录为 v2,暂无更早版本可对照。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v2 · 2026-11-19 20:17 · 最新观测版本

A Physics-Consistent Benchmark for Contact-Rich Human-Robot Interaction in Assistive Care

Conventional task-level evaluation asks whether a robot policy completes a specified action, but can miss failures that emerge only during physical human contact. This limitation is critical in contact-rich assistive tasks, where meaningful evaluation requires a physically responsive human, interaction-quality assessment beyond task success, and a leak-free observer-scorer protocol. We introduce a physics-consistent benchmark for contact-rich human-robot interaction, instantiated in robot-assisted bathing. The benchmark combines a deformable, passively responding human, physics-aware scores alongside task-level success, and a frozen vision-only / scorer-only evaluation protocol. To establish physical validity, region-wise simulated responses are calibrated against force-indentation measurements from Franka impedance pushes on a medical-care manikin. Under a frozen T1-T7 protocol with 140 runs per method, an LLM-augmented state machine (State Machine) achieves 72.9% task success but drops to 56.4% after correct-region and force-safety screening; VoxPoser produces lighter and more stable contact but completes only 27.9% of trials; and zero-shot pi0.5 achieves 0.7% task success with no correct-region or safety-gated successes. These results show that task completion alone does not imply physically valid contact and motivate physics-aware screening before deployment of contact-rich assistive robot policies.

查看此版本解读 →查看此版本原文 ↗