跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2609.34091 · v2

From Perturbation Sensitivity to Sparse Autoencoder Feature Interpretation: An EEG Foundation-Model Case Study

首次提交 2026-09-28 09:31
版本更新 2026-11-03 19:44
雷达观测 2026-11-04 23:39
arXiv ↗PDF ↗

摘要

Sparse autoencoders (SAEs) split a model's internal activity into many sparse units, or latents, and a latent is often named after a concept when removing that concept from the input changes its activity. We identify a consequential confound in this inference: if removing the concept changes the input more than the comparison edit does, a larger response may reflect a larger edit rather than the concept. Brain-signal (electroencephalography, EEG) models provide a controlled test, because how much an edit changes the EEG input can be measured directly. We measure the SAE response as the change in how often each latent is active, averaged over all latents. Across 27 combinations of model, dataset, and layer, removing the 8--12 Hz alpha band changes this response 7.33 times as much as removing an equally wide 30--34 Hz control band, but it also changes the signal far more. Matching the two edits per trial on squared time-domain distortion lowers the mean ratio to 1.42, with 19 of 27 combinations above one. Matching thus substantially reduces, but does not eliminate, the alpha--control contrast. The residual supports relative sensitivity under this single control, not general spectral specificity or an individual alpha-representing latent. We use an evidence-to-claim map to separate what this comparison supports from stronger claims of specificity and feature semantics.

作者备注:Revised version with expanded experimental analysis and discussion of limitations

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只观测到一个版本,无法比较变化。之后收录新版本时,会在这里对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v2 · 2026-11-03 19:44 · 最新观测版本

From Perturbation Sensitivity to Sparse Autoencoder Feature Interpretation: An EEG Foundation-Model Case Study

Sparse autoencoders (SAEs) split a model's internal activity into many sparse units, or latents, and a latent is often named after a concept when removing that concept from the input changes its activity. We identify a consequential confound in this inference: if removing the concept changes the input more than the comparison edit does, a larger response may reflect a larger edit rather than the concept. Brain-signal (electroencephalography, EEG) models provide a controlled test, because how much an edit changes the EEG input can be measured directly. We measure the SAE response as the change in how often each latent is active, averaged over all latents. Across 27 combinations of model, dataset, and layer, removing the 8--12 Hz alpha band changes this response 7.33 times as much as removing an equally wide 30--34 Hz control band, but it also changes the signal far more. Matching the two edits per trial on squared time-domain distortion lowers the mean ratio to 1.42, with 19 of 27 combinations above one. Matching thus substantially reduces, but does not eliminate, the alpha--control contrast. The residual supports relative sensitivity under this single control, not general spectral specificity or an individual alpha-representing latent. We use an evidence-to-claim map to separate what this comparison supports from stronger claims of specificity and feature semantics.

查看此版本解读 →查看此版本原文 ↗