← 研踪 PaperTrailarXiv:2610.09505 · v3
Bias-Aware Adjoint Calibration and Optimal Control of Stochastic Multiscale Bioprocess Digital Twins
首次提交 2026-10-07 14:03
版本更新 2026-11-11 10:10
雷达观测 2026-11-13 10:09
摘要
We develop a bias-aware digital-twin calibration and control framework for multiscale bioprocess models within a biological systems-of-systems (Bio-SoS) paradigm. The digital twin is represented by a stochastic differential equation (SDE) model and calibrated from sparse observations using quasi-likelihood estimation and adjoint sensitivity analysis. SDE generator-based moment expansions characterize truncation-induced parameter bias, while forward-backward adjoints quantify how calibration uncertainty propagates to value functions and policy performance. The resulting parameter-error distribution supports both policy-directed data acquisition and uncertainty-aware policy optimization through a second-order Gaussian-averaged objective. We characterize the asymptotic behavior of the resulting exploration criterion and derive a physical-system performance under the optimized policy. To implement these ideas, we develop an Actor-Simulator algorithm that jointly updates model parameters, selects informative experiments, and optimizes control policies. Numerical studies demonstrate improved calibration accuracy, sample efficiency, and control performance relative to state-of-the-art baselines.
作者备注:35 pages, 8 figures
观测到的版本
相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。
v3 · 2026-11-11 10:10 · 最新观测版本
Bias-Aware Adjoint Calibration and Optimal Control of Stochastic Multiscale Bioprocess Digital Twins
We develop a bias-aware digital-twin calibration and control framework for multiscale bioprocess models within a biological systems-of-systems (Bio-SoS) paradigm. The digital twin is represented by a stochastic differential equation (SDE) model and calibrated from sparse observations using quasi-likelihood estimation and adjoint sensitivity analysis. SDE generator-based moment expansions characterize truncation-induced parameter bias, while forward-backward adjoints quantify how calibration uncertainty propagates to value functions and policy performance. The resulting parameter-error distribution supports both policy-directed data acquisition and uncertainty-aware policy optimization through a second-order Gaussian-averaged objective. We characterize the asymptotic behavior of the resulting exploration criterion and derive a physical-system performance under the optimized policy. To implement these ideas, we develop an Actor-Simulator algorithm that jointly updates model parameters, selects informative experiments, and optimizes control policies. Numerical studies demonstrate improved calibration accuracy, sample efficiency, and control performance relative to state-of-the-art baselines.
查看此版本解读 →查看此版本原文 ↗