跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2610.39065 · v1

Tabular foundation models are not a shortcut to calibrated clinical risk prediction: a pre-registered simulation against the true risk

首次提交 2026-10-29 07:51
版本更新 2026-10-29 07:51
雷达观测 2026-10-30 11:25
arXiv ↗PDF ↗

摘要

Tabular foundation models are pretrained networks that predict risk from a table without fitting a model. Whether their risks are correct (calibrated) has been judged on real data, where true risk is unknown. In a pre-registered simulation with known true risks, we compared TabPFN-3.5, TabICLv2 and Mitra-v2 with Firth logistic regression with intercept correction (FLIC) in 58 scenarios and 1,000 random designs, then on four clinical data sets. Foundation models were not a shortcut to calibration. Their calibration slope matched FLIC's within the pre-registered margin in 36 or 37 of 48 core scenarios and was better only at n = 200 with a 3% event rate. Even 3,000 patients were often not enough: with FLIC, TabPFN-3.5 or Mitra-v2, 63%-83% of samples gave risks close to the truth in average, intercept and slope at event rates of 10% and 30%, and 35%-50% at 3%. TabICLv2 did worse (8%-39% and 1%-3%). Across the random designs, foundation models had a lower true calibration error than FLIC beyond the margin in 25%-38% and a higher one in none, though small losses were predicted at n = 3000. On real data, no model resisted a change in event rate between populations; recalibration on 500 local patients largely repaired it.

作者备注:37 pages, 7 figures, 1 table; Supplementary Information (55 pages) as an ancillary file. Pre-registered on OSF Registries (doi:10.17605/OSF.IO/8HMTZ). Code: doi:10.5281/zenodo.23737378; benchmark data: doi:10.5281/zenodo.23737416

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只观测到一个版本,无法比较变化。之后收录新版本时,会在这里对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-10-29 07:51 · 最新观测版本

Tabular foundation models are not a shortcut to calibrated clinical risk prediction: a pre-registered simulation against the true risk

Tabular foundation models are pretrained networks that predict risk from a table without fitting a model. Whether their risks are correct (calibrated) has been judged on real data, where true risk is unknown. In a pre-registered simulation with known true risks, we compared TabPFN-3.5, TabICLv2 and Mitra-v2 with Firth logistic regression with intercept correction (FLIC) in 58 scenarios and 1,000 random designs, then on four clinical data sets. Foundation models were not a shortcut to calibration. Their calibration slope matched FLIC's within the pre-registered margin in 36 or 37 of 48 core scenarios and was better only at n = 200 with a 3% event rate. Even 3,000 patients were often not enough: with FLIC, TabPFN-3.5 or Mitra-v2, 63%-83% of samples gave risks close to the truth in average, intercept and slope at event rates of 10% and 30%, and 35%-50% at 3%. TabICLv2 did worse (8%-39% and 1%-3%). Across the random designs, foundation models had a lower true calibration error than FLIC beyond the margin in 25%-38% and a higher one in none, though small losses were predicted at n = 3000. On real data, no model resisted a change in event rate between populations; recalibration on 500 local patients largely repaired it.

查看此版本解读 →查看此版本原文 ↗