← 研踪 PaperTrailarXiv:2610.40110 · v1
D-MOD: Diffusion mode estimation for accelerated MRI
首次提交 2026-10-29 22:12
版本更新 2026-10-29 22:12
雷达观测 2026-10-30 13:28
摘要
Diffusion models are powerful priors for accelerated MRI reconstruction, but most current methods are posterior samplers, which return a random draw from the posterior. A reproducible and high-quality reconstruction often requires averaging many samples, resulting in a high computational cost. We introduce D-MOD, a fast algorithm that instead provides a posterior mode. It uses a minorize-maximize algorithm on a lower bound of the smoothed log-posterior, which provably increases the objective. Each iteration draws S noisy samples of the current estimate at the current noise level, denoises them with a pretrained diffusion model, and combines their average with the measured k-space through a conjugate-gradient (CG) solve. We anneal the noise levels, as the distance between the bound and its target decays quadratically with noise. On fastMRI brain (T1, T2, FLAIR), a single D-MOD reconstruction exceeds, in PSNR, the 10-sample finite-MMSE estimates of DPS, DAPS and SNORE-P and stays within 0.31 dB of the strongest baselines (DiffPIR, DDS). This approach thus provides a fast deterministic reconstruction algorithm (11-73 times faster than MMSE estimates), which is useful in a clinical setting.
观测到的版本
相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。
v1 · 2026-10-29 22:12 · 最新观测版本
D-MOD: Diffusion mode estimation for accelerated MRI
Diffusion models are powerful priors for accelerated MRI reconstruction, but most current methods are posterior samplers, which return a random draw from the posterior. A reproducible and high-quality reconstruction often requires averaging many samples, resulting in a high computational cost. We introduce D-MOD, a fast algorithm that instead provides a posterior mode. It uses a minorize-maximize algorithm on a lower bound of the smoothed log-posterior, which provably increases the objective. Each iteration draws S noisy samples of the current estimate at the current noise level, denoises them with a pretrained diffusion model, and combines their average with the measured k-space through a conjugate-gradient (CG) solve. We anneal the noise levels, as the distance between the bound and its target decays quadratically with noise. On fastMRI brain (T1, T2, FLAIR), a single D-MOD reconstruction exceeds, in PSNR, the 10-sample finite-MMSE estimates of DPS, DAPS and SNORE-P and stays within 0.31 dB of the strongest baselines (DiffPIR, DDS). This approach thus provides a fast deterministic reconstruction algorithm (11-73 times faster than MMSE estimates), which is useful in a clinical setting.
查看此版本解读 →查看此版本原文 ↗