跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2610.40252 · v1

Conformal Annotation with Randomized Expert Review: Application to Online Cell-Type Labeling

首次提交 2026-10-29 23:20
版本更新 2026-10-29 23:20
雷达观测 2026-10-30 13:28
arXiv ↗PDF ↗

摘要

Artificial intelligence (AI) models can accelerate cell-type annotation in digital pathology, but safely scaling their use requires determining, with error control, which model-generated labels can be accepted without expert review. This is challenging in evolving workflows because cell morphology and type composition may change across tissue regions and slides, making one-time calibration unreliable. We propose Conformal Annotation with Randomized Expert review under Distribution shift (CARED), a distribution-free framework that leverages randomized expert audit to achieve long-run error control for AI-assisted annotation under distribution shift. For each incoming batch, CARED uniformly selects a subset of cases for expert review and uses the acquired labels to calibrate later decisions. Among unreviewed cases, CARED determines a subset of them to safely skip expert labeling, while suggesting candidate labels for the others for downstream resolution. We prove that this workflow provides long-run control of cumulative error over both the full stream and the cells outside of the audit sample, without stationarity or exchangeability assumptions. We further enhance the framework by introducing class-conditional guarantees to ensure error control within important but rare cell types, together with a utility module to target more automatic resolutions, smaller candidate sets, and greater biological coherence, without compromising validity. Experiments on pancreas, lung, and ovary annotation streams, together with a stream constructed from real expert annotations, show that CARED controls the cumulative errors while a substantial fraction of cells (up to 70%) bypass expert review.

作者备注:48 pages, 17 figures

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只观测到一个版本,无法比较变化。之后收录新版本时,会在这里对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-10-29 23:20 · 最新观测版本

Conformal Annotation with Randomized Expert Review: Application to Online Cell-Type Labeling

Artificial intelligence (AI) models can accelerate cell-type annotation in digital pathology, but safely scaling their use requires determining, with error control, which model-generated labels can be accepted without expert review. This is challenging in evolving workflows because cell morphology and type composition may change across tissue regions and slides, making one-time calibration unreliable. We propose Conformal Annotation with Randomized Expert review under Distribution shift (CARED), a distribution-free framework that leverages randomized expert audit to achieve long-run error control for AI-assisted annotation under distribution shift. For each incoming batch, CARED uniformly selects a subset of cases for expert review and uses the acquired labels to calibrate later decisions. Among unreviewed cases, CARED determines a subset of them to safely skip expert labeling, while suggesting candidate labels for the others for downstream resolution. We prove that this workflow provides long-run control of cumulative error over both the full stream and the cells outside of the audit sample, without stationarity or exchangeability assumptions. We further enhance the framework by introducing class-conditional guarantees to ensure error control within important but rare cell types, together with a utility module to target more automatic resolutions, smaller candidate sets, and greater biological coherence, without compromising validity. Experiments on pancreas, lung, and ovary annotation streams, together with a stream constructed from real expert annotations, show that CARED controls the cumulative errors while a substantial fraction of cells (up to 70%) bypass expert review.

查看此版本解读 →查看此版本原文 ↗