← 研踪 PaperTrailarXiv:2610.41112 · v2
Calibration of Large Model Quantization based on HiFloat4 Format
首次提交 2026-10-30 09:10
版本更新 2026-11-03 12:34
雷达观测 2026-11-04 23:40
摘要
Quantization of Large Language Models (LLMs) has become increasingly important for reducing the computational costs and resource requirements for practical deployment. Growing interest in this area has motivated the community to move beyond 8-bit quantization towards 4-bit precision, leading to the development of customized 4-bit formats such as MXFP4 and NVFP4. Recently, HiFloat4 (HiF4) has emerged as a competitive alternative which adopts a Block Floating-Point (BFP) format with a three-level scaling hierarchy, thereby achieving a significantly larger dynamic range. While quantization can substantially reduce memory usage and accelerate inference, it frequently introduces accuracy degradation. Calibration is therefore essential for narrowing the performance gap between low-precision quantized models and their full-precision counterparts. Nevertheless, existing calibration methods are mainly designed and validated using integer-precision formats, such as INT4, lacking support for HiF4 due to its hierarchical BFP structure. In this paper, we investigate three calibration approaches, namely HiGPTQ, HiAutoRound, and HiFlatQuant, to further enhance model quantization based on the HiF4 format. Extensive experiment s demonstrate that all three proposed approaches improve inference accuracy compared with direct HiF4 conversion, reducing the gap between HiF4 and BF16 to less than 1% and outperforming the state-of-the-art NVFP4 format across various models and downstream tasks.
作者备注:update typo
观测到的版本
相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。
v2 · 2026-11-03 12:34 · 最新观测版本
Calibration of Large Model Quantization based on HiFloat4 Format
Quantization of Large Language Models (LLMs) has become increasingly important for reducing the computational costs and resource requirements for practical deployment. Growing interest in this area has motivated the community to move beyond 8-bit quantization towards 4-bit precision, leading to the development of customized 4-bit formats such as MXFP4 and NVFP4. Recently, HiFloat4 (HiF4) has emerged as a competitive alternative which adopts a Block Floating-Point (BFP) format with a three-level scaling hierarchy, thereby achieving a significantly larger dynamic range. While quantization can substantially reduce memory usage and accelerate inference, it frequently introduces accuracy degradation. Calibration is therefore essential for narrowing the performance gap between low-precision quantized models and their full-precision counterparts. Nevertheless, existing calibration methods are mainly designed and validated using integer-precision formats, such as INT4, lacking support for HiF4 due to its hierarchical BFP structure. In this paper, we investigate three calibration approaches, namely HiGPTQ, HiAutoRound, and HiFlatQuant, to further enhance model quantization based on the HiF4 format. Extensive experiment s demonstrate that all three proposed approaches improve inference accuracy compared with direct HiF4 conversion, reducing the gap between HiF4 and BF16 to less than 1% and outperforming the state-of-the-art NVFP4 format across various models and downstream tasks.
查看此版本解读 →查看此版本原文 ↗