跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2611.02736 · v1

Feature extraction for LSTM-based finger-joint angle estimation from sEMG

首次提交 2026-11-02 16:25
版本更新 2026-11-02 16:25
雷达观测 2026-11-04 23:42
arXiv ↗PDF ↗

摘要

Continuous estimation of finger-joint angles from surface electromyography (sEMG) is a promising approach for controlling dexterous myoelectric prostheses. Deep time series models have been applied successfully in this context, typically relying on feature extraction rather than raw signals, given limited subject-specific data. Various time-domain and frequency-domain features can be used, extracted for a given window and step size. This study systematically investigates these three design choices for Long Short-Term Memory (LSTM) regression on the Ninapro DB2 dataset. Window sizes from 300 to 1200 ms and step sizes from 10 to 100 ms were evaluated in combination with six time- and frequency-domain features. Models were evaluated using regression performance metrics, inference time, and memory footprint to assess feasibility on embedded microcontroller hardware suitable for a prosthetic device. A 300 ms window with a 100 ms step, paired with either the Mean Absolute Value (MAV) or Root Mean Squared (RMS) feature, yielded the best performance (test PCC of 0.779 +/- 0.080 / 0.779 +/- 0.085). Window size, step size, and feature choice were found to interact non-trivially: jointly tuning them can improve both accuracy and computational feasibility for real-time, embedded myoelectric control.

作者备注:20 pages, 8 figures

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只观测到一个版本,无法比较变化。之后收录新版本时,会在这里对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-02 16:25 · 最新观测版本

Feature extraction for LSTM-based finger-joint angle estimation from sEMG

Continuous estimation of finger-joint angles from surface electromyography (sEMG) is a promising approach for controlling dexterous myoelectric prostheses. Deep time series models have been applied successfully in this context, typically relying on feature extraction rather than raw signals, given limited subject-specific data. Various time-domain and frequency-domain features can be used, extracted for a given window and step size. This study systematically investigates these three design choices for Long Short-Term Memory (LSTM) regression on the Ninapro DB2 dataset. Window sizes from 300 to 1200 ms and step sizes from 10 to 100 ms were evaluated in combination with six time- and frequency-domain features. Models were evaluated using regression performance metrics, inference time, and memory footprint to assess feasibility on embedded microcontroller hardware suitable for a prosthetic device. A 300 ms window with a 100 ms step, paired with either the Mean Absolute Value (MAV) or Root Mean Squared (RMS) feature, yielded the best performance (test PCC of 0.779 +/- 0.080 / 0.779 +/- 0.085). Window size, step size, and feature choice were found to interact non-trivially: jointly tuning them can improve both accuracy and computational feasibility for real-time, embedded myoelectric control.

查看此版本解读 →查看此版本原文 ↗