跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2611.02773 · v1

Molecular Communication for Plaque Sensing in a Vascular Bifurcation with Receiver Constraints

首次提交 2026-11-02 16:49
版本更新 2026-11-02 16:49
雷达观测 2026-11-04 23:42
arXiv ↗PDF ↗

摘要

Future molecular communication (MC) networks are envisioned to use the human cardiovascular system as a channel. Disease-related changes affect particle transport, allowing an MC receiver to also act as a sensor. In this work, we investigate plaque formation in a carotid bifurcation through a systematic fluid-dynamics simulation study with non-Newtonian blood rheology. We analyze how plaque geometry changes branch-specific particle reception and timing, and use these observations to estimate plaque-induced channel obstruction. At an illustrative reference of only 128 emitted particles, a 250 ms observation window and 50 ms temporal resolution, a Ridge detector estimates maximum local channel-width reduction with a mean absolute error of 8.30 percentage points. We evaluate robustness across system constraints like particle budgets, observation windows, branch access, detection efficiency, count resolution, and synchronization. Coarse counting has little effect when timing features remain available, whereas limited temporal resolution and clock uncertainty substantially affect short-window estimates. Extending the observation window to 1 s reduces these timing-related penalties. The results establish a baseline for plaque sensing from constrained MC observations and identify receiver capabilities relevant to the Internet of Bio-Nano Things.

作者备注:6 pages, 8 figures; submitted to IEEE ICC for review; Alexander Wietfeld and Luiz C. P. Wille contributed equally to this work

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只观测到一个版本,无法比较变化。之后收录新版本时,会在这里对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-02 16:49 · 最新观测版本

Molecular Communication for Plaque Sensing in a Vascular Bifurcation with Receiver Constraints

Future molecular communication (MC) networks are envisioned to use the human cardiovascular system as a channel. Disease-related changes affect particle transport, allowing an MC receiver to also act as a sensor. In this work, we investigate plaque formation in a carotid bifurcation through a systematic fluid-dynamics simulation study with non-Newtonian blood rheology. We analyze how plaque geometry changes branch-specific particle reception and timing, and use these observations to estimate plaque-induced channel obstruction. At an illustrative reference of only 128 emitted particles, a 250 ms observation window and 50 ms temporal resolution, a Ridge detector estimates maximum local channel-width reduction with a mean absolute error of 8.30 percentage points. We evaluate robustness across system constraints like particle budgets, observation windows, branch access, detection efficiency, count resolution, and synchronization. Coarse counting has little effect when timing features remain available, whereas limited temporal resolution and clock uncertainty substantially affect short-window estimates. Extending the observation window to 1 s reduces these timing-related penalties. The results establish a baseline for plaque sensing from constrained MC observations and identify receiver capabilities relevant to the Internet of Bio-Nano Things.

查看此版本解读 →查看此版本原文 ↗