跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2611.04126 · v1

GlucoAgent: Personalized Glucose Forecasting from Multimodal Personal Context

首次提交 2026-11-03 09:06
版本更新 2026-11-03 09:06
雷达观测 2026-11-04 23:40
arXiv ↗PDF ↗

摘要

Continuous glucose monitors, smartwatches, meal logs, and health profiles form a rich multimodal personal context that can significantly enhance glucose forecasting. However, existing methods struggle to effectively utilize these signals to improve glucose prediction because the relevance of different modalities varies drastically across individuals and time. We present GlucoAgent, an LLM-based agentic system that addresses this challenge through dynamic, case-by-case analysis at inference time. For each forecast, GlucoAgent writes and runs code over an individual's multimodal context and returns predictions with a reason and supporting evidence. The generated programs are highly diverse, ranging from retrieving similar past meals to fitting and back-testing physiological and statistical models. On CGMacros, a multimodal glucose dataset, GlucoAgent outperforms time series foundation models on every forecasting horizon, achieving an average RMSE of 22.5 mg/dL compared to 23.5 mg/dL of Chronos-2, the leading multimodal time series foundation model. Furthermore, GlucoAgent is highly effective at leveraging multimodal data. The addition of multimodal data reduces its average RMSE by 1.4 mg/dL (24.0 mg/dL to 22.5 mg/dL), compared to a marginal 0.3 mg/dL (23.8 mg/dL to 23.5 mg/dL) improvement for Chronos-2. This advantage is most pronounced in challenging post-meal windows, where GlucoAgent uses multimodal context to reduce 60-minute forecast RMSE by 4.6 mg/dL (31.0 mg/dL to 26.5 mg/dL), far exceeding the 0.8 mg/dL (31.9 mg/dL to 31.1 mg/dL) reduction achieved by Chronos-2.

期刊信息:GenAI for Health Workshop @ NeurIPS 2026, Sydney

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只观测到一个版本,无法比较变化。之后收录新版本时,会在这里对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-03 09:06 · 最新观测版本

GlucoAgent: Personalized Glucose Forecasting from Multimodal Personal Context

Continuous glucose monitors, smartwatches, meal logs, and health profiles form a rich multimodal personal context that can significantly enhance glucose forecasting. However, existing methods struggle to effectively utilize these signals to improve glucose prediction because the relevance of different modalities varies drastically across individuals and time. We present GlucoAgent, an LLM-based agentic system that addresses this challenge through dynamic, case-by-case analysis at inference time. For each forecast, GlucoAgent writes and runs code over an individual's multimodal context and returns predictions with a reason and supporting evidence. The generated programs are highly diverse, ranging from retrieving similar past meals to fitting and back-testing physiological and statistical models. On CGMacros, a multimodal glucose dataset, GlucoAgent outperforms time series foundation models on every forecasting horizon, achieving an average RMSE of 22.5 mg/dL compared to 23.5 mg/dL of Chronos-2, the leading multimodal time series foundation model. Furthermore, GlucoAgent is highly effective at leveraging multimodal data. The addition of multimodal data reduces its average RMSE by 1.4 mg/dL (24.0 mg/dL to 22.5 mg/dL), compared to a marginal 0.3 mg/dL (23.8 mg/dL to 23.5 mg/dL) improvement for Chronos-2. This advantage is most pronounced in challenging post-meal windows, where GlucoAgent uses multimodal context to reduce 60-minute forecast RMSE by 4.6 mg/dL (31.0 mg/dL to 26.5 mg/dL), far exceeding the 0.8 mg/dL (31.9 mg/dL to 31.1 mg/dL) reduction achieved by Chronos-2.

查看此版本解读 →查看此版本原文 ↗