← 研踪 PaperTrailarXiv:2611.04481 · v1
Goal-Driven Autonomous Optical Experimentation via a Self-Recursive Hardware-Software Harness
首次提交 2026-11-03 16:13
版本更新 2026-11-03 16:13
雷达观测 2026-11-04 23:39
摘要
We propose goal-driven self-recursive optical research in which agents use physical evidence to revise the hardware, software, models, and protocols used to pursue a scientific goal. The framework can be instantiated with different stimulus systems and measurement devices. We formalize its updates and derive a relation between physical attainability, command access, and model approximation error. We demonstrate the concept in an optical see-through color-matching case study using an iPad, RayNeo X3 glasses, and a TOP 300 probe coupled to a CAS140D spectroradiometer, both from Instrument Systems. A revised glasses application adds USB-controlled RGB holds and frame acknowledgements, keeping model-generated colors displayed during spectral acquisition. The interface passes 12 live control checks. Spectral feedback reduces one target color difference from 19.756 to 1.211 ΔE_76^*; all five targets improve in a separate comparison. These measurements demonstrate the concept in one configuration. The resulting software and protocols remain available for subsequent investigations.
观测到的版本
相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。
v1 · 2026-11-03 16:13 · 最新观测版本
Goal-Driven Autonomous Optical Experimentation via a Self-Recursive Hardware-Software Harness
We propose goal-driven self-recursive optical research in which agents use physical evidence to revise the hardware, software, models, and protocols used to pursue a scientific goal. The framework can be instantiated with different stimulus systems and measurement devices. We formalize its updates and derive a relation between physical attainability, command access, and model approximation error. We demonstrate the concept in an optical see-through color-matching case study using an iPad, RayNeo X3 glasses, and a TOP 300 probe coupled to a CAS140D spectroradiometer, both from Instrument Systems. A revised glasses application adds USB-controlled RGB holds and frame acknowledgements, keeping model-generated colors displayed during spectral acquisition. The interface passes 12 live control checks. Spectral feedback reduces one target color difference from 19.756 to 1.211 ΔE_76^*; all five targets improve in a separate comparison. These measurements demonstrate the concept in one configuration. The resulting software and protocols remain available for subsequent investigations.
查看此版本解读 →查看此版本原文 ↗