Pediatric ECG foundation model via adult-to-pediatric fine-tuning: downstream tasks and clinical evaluation

首次提交 2026-11-05 17:36
版本更新 2026-11-05 17:36
雷达观测 2026-11-06 11:06
arXiv ↗PDF ↗

摘要

Pediatric electrocardiogram (ECG) interpretation is complicated by age-dependent electrophysiological changes that limit direct transfer of adult AI models. We asked whether an adult ECG foundation model could be adapted to pediatric ECGs. Using 339,563 12-lead ECGs from 238,189 children, we compared direct application, pediatric fine-tuning, and training from scratch under an identical architecture. Direct transfer was poor (mean AUC 0.8256). Fine-tuning reached 0.9695, above de novo training (0.9661), and attained 0.9079 using only 1% of training data. On 10,999 external ECGs, fine-tuning achieved a mean AUC of 0.9385 across 30 labels. It generalized to age regression (MAE 1.12 years) and congenital heart disease classification (AUC 0.9562). Across 17 clinicians and 100 cases, diagnostic accuracy rose from 56.8% to 65.4% (p < 0.001) and did not decline when AI erred. Adult ECG foundation models require pediatric adaptation; fine-tuning offers a data-efficient route to scalable pediatric ECG AI.

作者备注:20 pages,3 figures

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只观测到一个版本,无法比较变化。之后收录新版本时,会在这里对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-05 17:36 · 最新观测版本

Pediatric ECG foundation model via adult-to-pediatric fine-tuning: downstream tasks and clinical evaluation

Pediatric electrocardiogram (ECG) interpretation is complicated by age-dependent electrophysiological changes that limit direct transfer of adult AI models. We asked whether an adult ECG foundation model could be adapted to pediatric ECGs. Using 339,563 12-lead ECGs from 238,189 children, we compared direct application, pediatric fine-tuning, and training from scratch under an identical architecture. Direct transfer was poor (mean AUC 0.8256). Fine-tuning reached 0.9695, above de novo training (0.9661), and attained 0.9079 using only 1% of training data. On 10,999 external ECGs, fine-tuning achieved a mean AUC of 0.9385 across 30 labels. It generalized to age regression (MAE 1.12 years) and congenital heart disease classification (AUC 0.9562). Across 17 clinicians and 100 cases, diagnostic accuracy rose from 56.8% to 65.4% (p < 0.001) and did not decline when AI erred. Adult ECG foundation models require pediatric adaptation; fine-tuning offers a data-efficient route to scalable pediatric ECG AI.

查看此版本解读 →查看此版本原文 ↗