arXiv:2611.08084 · v1

Winding-Pack Quench Simulation of Stellarator Coils: Hydraulic Field-Network Coupling and Transverse Heat Conduction in OPENSC$^2$

首次提交 2026-11-05 22:31
版本更新 2026-11-05 22:31
雷达观测 2026-11-06 12:09
arXiv ↗PDF ↗

摘要

Quench propagation in cable-in-conduit conductors is thermo-hydraulically driven, yet existing 1D models treat a conductor as one straight adiabatic cable with prescribed pressure and mass-flow boundaries, so secondary quenches and flow redistribution between windings cannot be resolved. We extend the open-source code OPENSC$^2$ with transverse heat conduction between turns, a 3D field resolving the current-sharing temperature, induced losses, and a lumped hydraulic network coupled to the conductors by a mass-flow formulation. Validated against the 2006 W7-X coil tests, it predicts the quench site, cuts the outlet-temperature error from 55 K to 12 K, and reproduces the neighboring windings' heating as flow reversal through the coil inlet.

作者备注:31 pages, 24 figures, 2 tables. Submitted for publication in Superconductor Science and Technology

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只观测到一个版本,无法比较变化。之后收录新版本时,会在这里对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-05 22:31 · 最新观测版本

Winding-Pack Quench Simulation of Stellarator Coils: Hydraulic Field-Network Coupling and Transverse Heat Conduction in OPENSC$^2$

Quench propagation in cable-in-conduit conductors is thermo-hydraulically driven, yet existing 1D models treat a conductor as one straight adiabatic cable with prescribed pressure and mass-flow boundaries, so secondary quenches and flow redistribution between windings cannot be resolved. We extend the open-source code OPENSC$^2$ with transverse heat conduction between turns, a 3D field resolving the current-sharing temperature, induced losses, and a lumped hydraulic network coupled to the conductors by a mass-flow formulation. Validated against the 2006 W7-X coil tests, it predicts the quench site, cuts the outlet-temperature error from 55 K to 12 K, and reproduces the neighboring windings' heating as flow reversal through the coil inlet.

查看此版本解读 →查看此版本原文 ↗