跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2611.11753 · v1

SpinSCI: Mask-Conditioned Spatial-Temporal Spin Transformer for Video Snapshot Compressive Imaging

首次提交 2026-11-09 09:49
版本更新 2026-11-09 09:49
雷达观测 2026-11-10 13:18
arXiv ↗PDF ↗

摘要

Video snapshot compressive imaging (SCI) recovers multiple frames from one spatiotemporally coded measurement. This paper proposes SpinSCI, a mask-conditioned Spatial-Temporal Spin Transformer whose Mask-Conditioned Ising Refinement Block (MC-IRB) combines attention logits and sensing information to form signed spin couplings. Finite mean-field updates gate residual feature refinement. Physics-guided initialization and final data consistency incorporate the measurement model. Compared with HiSViT9_9, SpinSCI achieves average PSNR gains of 0.51 dB, 0.23 dB, and 0.04 dB on small-scale gray, mid-scale color, and large-scale color benchmarks, respectively, with 16.9% fewer parameters, 21.0-21.6% fewer FLOPs, 17.1-49.9% lower latency, and 62.3-63.3% lower peak memory. Relative to DU-9stg, average PSNR differs by at most 0.13 dB across these benchmarks, with 28.2-28.7% fewer FLOPs, 64.6-71.7% lower inference latency, and 30.1-35.0% lower peak memory. Qualitative comparisons on the real benchmark further show recovery of fine details and textures. Code and reference checkpoints are available at https://github.com/skethz/SpinSCI.

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只收录了一个版本。收录下一版后,可以对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-09 09:49 · 最新观测版本

SpinSCI: Mask-Conditioned Spatial-Temporal Spin Transformer for Video Snapshot Compressive Imaging

Video snapshot compressive imaging (SCI) recovers multiple frames from one spatiotemporally coded measurement. This paper proposes SpinSCI, a mask-conditioned Spatial-Temporal Spin Transformer whose Mask-Conditioned Ising Refinement Block (MC-IRB) combines attention logits and sensing information to form signed spin couplings. Finite mean-field updates gate residual feature refinement. Physics-guided initialization and final data consistency incorporate the measurement model. Compared with HiSViT9_9, SpinSCI achieves average PSNR gains of 0.51 dB, 0.23 dB, and 0.04 dB on small-scale gray, mid-scale color, and large-scale color benchmarks, respectively, with 16.9% fewer parameters, 21.0-21.6% fewer FLOPs, 17.1-49.9% lower latency, and 62.3-63.3% lower peak memory. Relative to DU-9stg, average PSNR differs by at most 0.13 dB across these benchmarks, with 28.2-28.7% fewer FLOPs, 64.6-71.7% lower inference latency, and 30.1-35.0% lower peak memory. Qualitative comparisons on the real benchmark further show recovery of fine details and textures. Code and reference checkpoints are available at https://github.com/skethz/SpinSCI.

查看此版本解读 →查看此版本原文 ↗