跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2611.19297 · v1

Where Mixture Recognition Fails: An Ingredient-Level Audit of Unseen Combinations in SmellNet

首次提交 2026-11-14 17:48
版本更新 2026-11-14 17:48
雷达观测 2026-11-17 12:06
arXiv ↗PDF ↗

摘要

An electronic nose must name every ingredient of a mixture, including combinations it has never measured. SmellNet, a public benchmark for this task, scores ingredients with a hit rate that is told how many each sample contains. We audit what this protocol hides. We hold out ingredient combinations from the SmellNet training data, evaluate four architectures (MLP, CNN, LSTM and a Transformer encoder) without revealing the ingredient count, and repeat the evaluation once on the official unseen split. Under the count-informed protocol, 90-96% of mixtures receive an ingredient that is absent, on our folds and on the official split alike. On our folds, every model identifies one ingredient reliably but the second rarely, and it completes the pair with a familiar training partner about twice as often as chance. On the official split, even the first-ranked ingredient is correct in only 29-46% of binary mixtures, often because a frequent training ingredient that is absent from every test pair is ranked first, and on its combinations that are truly absent from training no model names both ingredients in more than 1.2% of them. The failures fall on the same ingredients for every architecture, and a frequency correction only moves errors between ingredients. Mixture recognition is therefore limited by ingredients the models cannot separate and by a preference for frequent ingredients, not by the architecture, and it should be evaluated with set-level errors and without oracle cardinality.

作者备注:6 pages, 4 tables, 2 figures

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只收录了一个版本。收录下一版后,可以对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-14 17:48 · 最新观测版本

Where Mixture Recognition Fails: An Ingredient-Level Audit of Unseen Combinations in SmellNet

An electronic nose must name every ingredient of a mixture, including combinations it has never measured. SmellNet, a public benchmark for this task, scores ingredients with a hit rate that is told how many each sample contains. We audit what this protocol hides. We hold out ingredient combinations from the SmellNet training data, evaluate four architectures (MLP, CNN, LSTM and a Transformer encoder) without revealing the ingredient count, and repeat the evaluation once on the official unseen split. Under the count-informed protocol, 90-96% of mixtures receive an ingredient that is absent, on our folds and on the official split alike. On our folds, every model identifies one ingredient reliably but the second rarely, and it completes the pair with a familiar training partner about twice as often as chance. On the official split, even the first-ranked ingredient is correct in only 29-46% of binary mixtures, often because a frequent training ingredient that is absent from every test pair is ranked first, and on its combinations that are truly absent from training no model names both ingredients in more than 1.2% of them. The failures fall on the same ingredients for every architecture, and a frequency correction only moves errors between ingredients. Mixture recognition is therefore limited by ingredients the models cannot separate and by a preference for frequent ingredients, not by the architecture, and it should be evaluated with set-level errors and without oracle cardinality.

查看此版本解读 →查看此版本原文 ↗