← 研踪 PaperTrailarXiv:2611.19741 · v1
Where the Error Lives: Separating Lid-Edge and Body-Induced Error in Neural Pressure Prediction for 3D Cavity Flow
首次提交 2026-11-15 10:58
版本更新 2026-11-15 10:58
雷达观测 2026-11-17 12:06
摘要
Can a pressure surrogate score much better globally without better resolving the pressure around immersed bodies? We test this in a three-dimensional lid-driven cavity with an unregularized lid and centered pressure at native resolution. On 60 cases from 12 unseen geometries, with predictions sealed before the CFD truth existed, adding a body-free, Reynolds-conditioned reference correction to the same frozen surrogate lifted to lowers the mean full-volume relative error from 20.6% to 7.5%. In the post hoc regional analysis, the lid-edge junction occupies 1.5% of the fluid but holds 69% of the truth pressure energy and 95% of the uncorrected surrogate's squared error. Interior error changes by just +0.16% relative, and object-local peak error and recall change little on average. Retrospective ablations locate the learned term's contribution in the interior and near the bodies; rebasing on the reference lowers global error further with little change in cohort-mean near-body metrics. Reference-relative body-response error remains about 25% in the interior near-body band. Grid-refinement, lid-regularization and convergence checks delimit the numerical scope. In this benchmark, a large global gain chiefly reflects correction of a shared boundary field, not better resolution of the body response. We recommend reporting regional truth-energy and model-error shares alongside near-body and reference-relative body-response errors.
作者备注:37 pages, 10 figures
观测到的版本
相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。
v1 · 2026-11-15 10:58 · 最新观测版本
Where the Error Lives: Separating Lid-Edge and Body-Induced Error in Neural Pressure Prediction for 3D Cavity Flow
Can a pressure surrogate score much better globally without better resolving the pressure around immersed bodies? We test this in a three-dimensional lid-driven cavity with an unregularized lid and centered pressure at native resolution. On 60 cases from 12 unseen geometries, with predictions sealed before the CFD truth existed, adding a body-free, Reynolds-conditioned reference correction to the same frozen surrogate lifted to lowers the mean full-volume relative error from 20.6% to 7.5%. In the post hoc regional analysis, the lid-edge junction occupies 1.5% of the fluid but holds 69% of the truth pressure energy and 95% of the uncorrected surrogate's squared error. Interior error changes by just +0.16% relative, and object-local peak error and recall change little on average. Retrospective ablations locate the learned term's contribution in the interior and near the bodies; rebasing on the reference lowers global error further with little change in cohort-mean near-body metrics. Reference-relative body-response error remains about 25% in the interior near-body band. Grid-refinement, lid-regularization and convergence checks delimit the numerical scope. In this benchmark, a large global gain chiefly reflects correction of a shared boundary field, not better resolution of the body response. We recommend reporting regional truth-energy and model-error shares alongside near-body and reference-relative body-response errors.
查看此版本解读 →查看此版本原文 ↗