跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2611.20889 · v1

Comfort as a Constraint or as a Cost in Reinforcement Learning and Model Predictive Building Control

首次提交 2026-11-16 18:58
版本更新 2026-11-16 18:58
雷达观测 2026-11-17 17:11
arXiv ↗PDF ↗

摘要

A building controller that keeps a zone within comfort bounds at minimum energy can treat the bounds as a soft constraint, by adding the weighted violation to its cost, or as a hard constraint. We analyze the effect of the hard and the soft formulation of the same problem and isolate the effect of the formulation from the effect of the algorithm. To this end, we measure the difference in energy use between the two formulations on the BOPTEST bestest_hydronic_heat_pump case, in model predictive control (MPC) and in reinforcement learning (RL). The soft formulations are a weighted MPC and weighted SAC and DDPG learners, each at twelve weights. The hard formulations are an MPC with an exact penalty and the Lagrangian learners SAC-Lagrangian and primal-dual DDPG. We find that the hard formulations use more energy than the soft formulations at the largest weight, but violate the comfort bounds less. For a large weight, the soft formulation approaches the behavior of the hard formulation. The frontiers of the energy-comfort trade-off of the three weighted controllers lie close to each other, and the weight selects an operating point on this frontier. Under the soft formulation, the three algorithms reach very similar operating points, although at somewhat different weights. For this HVAC problem, the formulation and the weight thus affect the energy use more than the choice of algorithm.

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只收录了一个版本。收录下一版后,可以对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-16 18:58 · 最新观测版本

Comfort as a Constraint or as a Cost in Reinforcement Learning and Model Predictive Building Control

A building controller that keeps a zone within comfort bounds at minimum energy can treat the bounds as a soft constraint, by adding the weighted violation to its cost, or as a hard constraint. We analyze the effect of the hard and the soft formulation of the same problem and isolate the effect of the formulation from the effect of the algorithm. To this end, we measure the difference in energy use between the two formulations on the BOPTEST bestest_hydronic_heat_pump case, in model predictive control (MPC) and in reinforcement learning (RL). The soft formulations are a weighted MPC and weighted SAC and DDPG learners, each at twelve weights. The hard formulations are an MPC with an exact penalty and the Lagrangian learners SAC-Lagrangian and primal-dual DDPG. We find that the hard formulations use more energy than the soft formulations at the largest weight, but violate the comfort bounds less. For a large weight, the soft formulation approaches the behavior of the hard formulation. The frontiers of the energy-comfort trade-off of the three weighted controllers lie close to each other, and the weight selects an operating point on this frontier. Under the soft formulation, the three algorithms reach very similar operating points, although at somewhat different weights. For this HVAC problem, the formulation and the weight thus affect the energy use more than the choice of algorithm.

查看此版本解读 →查看此版本原文 ↗