← 研踪 PaperTrailarXiv:2611.23501 · v1
MedHarness: A Unified Budgeted Runtime for Reliable Medical Imaging Agents
首次提交 2026-11-18 04:50
版本更新 2026-11-18 04:50
雷达观测 2026-11-19 19:08
摘要
Medical imaging agents already return answers on heterogeneous imaging surfaces, yet deployment still faces a limited verification budget where each wrong accept can harm clinical trust. When a thin check and a deeper evidence pass disagree on the same case, deciding when to stop, open more evidence, repair, or reject without a shared controller remains ill-posed. Tool-using workflows often lock a surface-specific evidence order per dataset, or a private always-open full-depth verification path; those pipelines stay costly, leave many wrong accepts, and cannot share one controller across modalities. We present MedHarness, a registered multi-surface runtime reliability layer that reformulates post-answer control as shared decision-object attachment after a proposer's initial prediction. Under Shared Decision Object, Minimum-Sufficient Verification, and Intermediate Repair, one shared policy with surface recipe adapters lets a new imaging surface join the same stop / open-evidence / repair / reject controller by recipe registration. On a 512-case live pool, MedHarness cuts wrong accepts versus a full-verification baseline by about 47% and raises accepted accuracy to 83.2% vs. 72.9% at 86.1% coverage versus full release under that baseline. On a failure-enriched multi-surface stress ranking, the same controller cuts estimated remote service calls per case by about 71% versus that baseline under a matched context-load setting. A held-out three-surface check and an alternate language-model transfer keep the same control ordering. The code is available at https://anonymous.4open.science/r/MedHarness-paper-release-A7F3/.
观测到的版本
相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。
v1 · 2026-11-18 04:50 · 最新观测版本
MedHarness: A Unified Budgeted Runtime for Reliable Medical Imaging Agents
Medical imaging agents already return answers on heterogeneous imaging surfaces, yet deployment still faces a limited verification budget where each wrong accept can harm clinical trust. When a thin check and a deeper evidence pass disagree on the same case, deciding when to stop, open more evidence, repair, or reject without a shared controller remains ill-posed. Tool-using workflows often lock a surface-specific evidence order per dataset, or a private always-open full-depth verification path; those pipelines stay costly, leave many wrong accepts, and cannot share one controller across modalities. We present MedHarness, a registered multi-surface runtime reliability layer that reformulates post-answer control as shared decision-object attachment after a proposer's initial prediction. Under Shared Decision Object, Minimum-Sufficient Verification, and Intermediate Repair, one shared policy with surface recipe adapters lets a new imaging surface join the same stop / open-evidence / repair / reject controller by recipe registration. On a 512-case live pool, MedHarness cuts wrong accepts versus a full-verification baseline by about 47% and raises accepted accuracy to 83.2% vs. 72.9% at 86.1% coverage versus full release under that baseline. On a failure-enriched multi-surface stress ranking, the same controller cuts estimated remote service calls per case by about 71% versus that baseline under a matched context-load setting. A held-out three-surface check and an alternate language-model transfer keep the same control ordering. The code is available at https://anonymous.4open.science/r/MedHarness-paper-release-A7F3/.
查看此版本解读 →查看此版本原文 ↗