跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2611.23619 · v1

EEG2MCU: Sensing-to-Execution Co-Design for Wearable EEG Inference

首次提交 2026-11-18 07:20
版本更新 2026-11-18 07:20
雷达观测 2026-11-19 19:08
arXiv ↗PDF ↗

摘要

Wearable EEG inference is constrained not only by model size, but also by the channel-dependent sensing front end that must process high-dimensional inputs before compact downstream computation. We present EEG2MCU, a sensing-to-execution co-design framework that treats electrode count as a hardware design variable through task-aware montage selection. EEG2MCU retains a compact time-frequency representation and generates only the INT8 regions required by each first-layer tile, avoiding full input materialization. Halo reuse and access-aware placement across Flash, SRAM, and tightly coupled memory further reduce redundant generation and data movement. On a Cortex-M7 MCU, EEG2MCU reduces peak SRAM by 11.38x relative to the baseline, including a 1.71x reduction from the 62-to-19 electrode montage, while reducing latency by 2.57x and energy by 2.48x. It retains 94-96% of full-montage accuracy, demonstrating practical high-dimensional EEG inference under tight embedded-resource constraints.

作者备注:7 pages, 9 figures, 3 tables. Accepted at DATE 2027

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只收录了一个版本。收录下一版后,可以对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-18 07:20 · 最新观测版本

EEG2MCU: Sensing-to-Execution Co-Design for Wearable EEG Inference

Wearable EEG inference is constrained not only by model size, but also by the channel-dependent sensing front end that must process high-dimensional inputs before compact downstream computation. We present EEG2MCU, a sensing-to-execution co-design framework that treats electrode count as a hardware design variable through task-aware montage selection. EEG2MCU retains a compact time-frequency representation and generates only the INT8 regions required by each first-layer tile, avoiding full input materialization. Halo reuse and access-aware placement across Flash, SRAM, and tightly coupled memory further reduce redundant generation and data movement. On a Cortex-M7 MCU, EEG2MCU reduces peak SRAM by 11.38x relative to the baseline, including a 1.71x reduction from the 62-to-19 electrode montage, while reducing latency by 2.57x and energy by 2.48x. It retains 94-96% of full-montage accuracy, demonstrating practical high-dimensional EEG inference under tight embedded-resource constraints.

查看此版本解读 →查看此版本原文 ↗