← 研踪 PaperTrailarXiv:2611.25625 · v1
QUBO-based feature selection for MRI undersampling pattern design
首次提交 2026-11-19 15:10
版本更新 2026-11-19 15:10
雷达观测 2026-11-20 19:58
摘要
We formulate undersampling mask design for Cartesian magnetic resonance imaging (MRI) as a feature subset selection problem. Each sampling line is represented by a binary feature indicating whether it is included in each candidate mask. Using candidate masks and their training-set evaluations, we estimate mutual information (MI) and conditional mutual information (CMI). These estimates and a sampling-count penalty define a quadratic unconstrained binary optimization (QUBO) model. The model is solved using simulated annealing and quantum annealing to determine a feature subset and its corresponding sampling mask. We assess the selected subsets on the test set through zero-filled reconstruction in Fourier undersampling simulations using fastMRI knee magnitude reference images, with patient-disjoint training and test sets. At all six tested target sampling rates from 15% to 40%, the resulting reconstructions have lower mean root mean square error than those obtained with four conventional sampling methods. They also have higher mean structural similarity than those obtained using univariate mutual-information ranking at all tested rates. These results support information-theoretic feature selection as an approach to MRI undersampling mask design under the tested zero-filled simulation settings.
作者备注:20 pages, 3 figures
观测到的版本
相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。
v1 · 2026-11-19 15:10 · 最新观测版本
QUBO-based feature selection for MRI undersampling pattern design
We formulate undersampling mask design for Cartesian magnetic resonance imaging (MRI) as a feature subset selection problem. Each sampling line is represented by a binary feature indicating whether it is included in each candidate mask. Using candidate masks and their training-set evaluations, we estimate mutual information (MI) and conditional mutual information (CMI). These estimates and a sampling-count penalty define a quadratic unconstrained binary optimization (QUBO) model. The model is solved using simulated annealing and quantum annealing to determine a feature subset and its corresponding sampling mask. We assess the selected subsets on the test set through zero-filled reconstruction in Fourier undersampling simulations using fastMRI knee magnitude reference images, with patient-disjoint training and test sets. At all six tested target sampling rates from 15% to 40%, the resulting reconstructions have lower mean root mean square error than those obtained with four conventional sampling methods. They also have higher mean structural similarity than those obtained using univariate mutual-information ranking at all tested rates. These results support information-theoretic feature selection as an approach to MRI undersampling mask design under the tested zero-filled simulation settings.
查看此版本解读 →查看此版本原文 ↗