跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2611.25965 · v1

Power Setpoint Tracking for Large-Scale EV Charging: Transformer-Constrained Charging Policy Learning with Self-Tuning Constraint Prices

首次提交 2026-11-19 19:51
版本更新 2026-11-19 19:51
雷达观测 2026-11-20 16:53
arXiv ↗PDF ↗

摘要

In power setpoint tracking (PST), an operator follows a purchased charging profile without overloading shared transformers or undercharging vehicles. PST is cast as a constrained Markov decision process that minimizes tracking error subject to overload and mean user-satisfaction constraints. Transformer-Constrained Charging Policy Learning (TC-CPL) extends soft actor-critic with proportional-integral Lagrange-multiplier updates from measured violations, a residual on the incumbent dispatcher that is warm-started from its demonstrations, and a transformer-aware encoder shared by all ports. It observes no departure times or states of charge. Simulations (five seeds, 100 paired days) compare it with the incumbent, Round-Robin. On a 600-port, 122-substation district, raw overload falls from 3.59 to 0.0017 kWh/day (overloaded seed-days from 77% to 0.4%), and absolute tracking error falls by 27%. Delivered energy rises by 16%, and satisfaction rises from 0.959 to 0.989. On a 42-kW transformer with household load, overload falls from 1.86 to 0.0014 kWh/day and satisfaction rises from 0.974 to 0.985, but absolute tracking error is 22% higher. Against hand-set fixed multipliers, self-tuning is statistically indistinguishable on the district. On the single transformer, it raises satisfaction by 0.011 at similar overload, but a short sweep found a better-serving fixed pair. The overload multipliers stay below their cap.

作者备注:13 pages, 7 figures, 6 tables. Submitted to IEEE Transactions on Transportation Electrification

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只收录了一个版本。收录下一版后,可以对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-19 19:51 · 最新观测版本

Power Setpoint Tracking for Large-Scale EV Charging: Transformer-Constrained Charging Policy Learning with Self-Tuning Constraint Prices

In power setpoint tracking (PST), an operator follows a purchased charging profile without overloading shared transformers or undercharging vehicles. PST is cast as a constrained Markov decision process that minimizes tracking error subject to overload and mean user-satisfaction constraints. Transformer-Constrained Charging Policy Learning (TC-CPL) extends soft actor-critic with proportional-integral Lagrange-multiplier updates from measured violations, a residual on the incumbent dispatcher that is warm-started from its demonstrations, and a transformer-aware encoder shared by all ports. It observes no departure times or states of charge. Simulations (five seeds, 100 paired days) compare it with the incumbent, Round-Robin. On a 600-port, 122-substation district, raw overload falls from 3.59 to 0.0017 kWh/day (overloaded seed-days from 77% to 0.4%), and absolute tracking error falls by 27%. Delivered energy rises by 16%, and satisfaction rises from 0.959 to 0.989. On a 42-kW transformer with household load, overload falls from 1.86 to 0.0014 kWh/day and satisfaction rises from 0.974 to 0.985, but absolute tracking error is 22% higher. Against hand-set fixed multipliers, self-tuning is statistically indistinguishable on the district. On the single transformer, it raises satisfaction by 0.011 at similar overload, but a short sweep found a better-serving fixed pair. The overload multipliers stay below their cap.

查看此版本解读 →查看此版本原文 ↗