Rad-Linter checks chest X-ray reports against image-derived evidence to flag potential errors for review. A pretrained image classifier supplies scores for nine pathologies, and a 1.5B-parameter language model, fine-tuned with LoRA on 1,816 examples, checks their consistency with the report. We compare it with a keyword-and-negation rule baseline given the same reports and scores. Evaluation uses controlled report-score pairings from OpenI, with consistency labels derived from automatic report labels and score thresholds. Each counterfactual quad crosses two real reports with two real score vectors from other patients, creating two consistent and two inconsistent pairs. Every report and score vector occurs in both conditions, so either input alone permits only 50% accuracy. On 131 quads, Rad-Linter achieves 98.5% pair accuracy versus 80.5% for the rule baseline, and classifies all four pairs correctly in 94.4% of quads versus 56.5%. The checkers perform similarly on omission items, including unmentioned and negated findings; larger differences occur on the remaining item types, which require interpreting how findings are described. The same language model without fine-tuning remains near 50% accuracy. On a second set of 181 quads that also includes reports on which the automatic labelers disagree, pair accuracy is 93.4% versus 75.3%. These controlled results show that, given the same image-derived scores, a trained language model detects report-score inconsistencies more accurately than the tested rule baseline, with the advantage concentrated in interpreting how findings are worded.

作者备注:34 pages, 4 figures, including supplementary material

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只收录了一个版本。收录下一版后,可以对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-20 01:46 · 最新观测版本

Multimodal Error Detection in Chest X-ray Reports: A Large Language Model Reading Image Evidence

Rad-Linter checks chest X-ray reports against image-derived evidence to flag potential errors for review. A pretrained image classifier supplies scores for nine pathologies, and a 1.5B-parameter language model, fine-tuned with LoRA on 1,816 examples, checks their consistency with the report. We compare it with a keyword-and-negation rule baseline given the same reports and scores. Evaluation uses controlled report-score pairings from OpenI, with consistency labels derived from automatic report labels and score thresholds. Each counterfactual quad crosses two real reports with two real score vectors from other patients, creating two consistent and two inconsistent pairs. Every report and score vector occurs in both conditions, so either input alone permits only 50% accuracy. On 131 quads, Rad-Linter achieves 98.5% pair accuracy versus 80.5% for the rule baseline, and classifies all four pairs correctly in 94.4% of quads versus 56.5%. The checkers perform similarly on omission items, including unmentioned and negated findings; larger differences occur on the remaining item types, which require interpreting how findings are described. The same language model without fine-tuning remains near 50% accuracy. On a second set of 181 quads that also includes reports on which the automatic labelers disagree, pair accuracy is 93.4% versus 75.3%. These controlled results show that, given the same image-derived scores, a trained language model detects report-score inconsistencies more accurately than the tested rule baseline, with the advantage concentrated in interpreting how findings are worded.

查看此版本解读 →查看此版本原文 ↗