← 研踪 PaperTrailarXiv:2611.27397 · v1
AnyBodyCodec: A Shared Native Interface for Body-Model Conversion, Extension, and Humanoid Control
首次提交 2026-11-20 18:03
版本更新 2026-11-20 18:03
雷达观测 2026-11-23 14:16
摘要
Parametric body models expose incompatible pose and shape controls, tying humanoid policies to particular input formats. AnyBodyCodec learns a shared representation through native conversion, then reuses it for new body models and control with its core frozen. Encoders map MHR, SMPL-X, and SOMA to aligned slots; native decoders recover target controls. The 1.090M-parameter converter covers nine routes and reaches 16.801 mm input-reference MPJPE across six cross routes: the 2.887M Transformer bank reaches 16.390 mm and its parameter-matched version 18.866 mm. Three measured routes take 7.43-7.67 ms on an RTX 4090. Adding ANNY shows that comparable conversion accuracy can accompany different action consistency under one frozen controller. Under a matched PPO budget, aligned slots support 60.78% full-action success across three formats. Separate 160-hour training reaches 66.10% source-weighted validation success, and the controller is deployed qualitatively on a physical G1 through three visual front ends. Together, these results establish reuse through both native geometric fidelity and downstream policy compatibility.
观测到的版本
相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。
v1 · 2026-11-20 18:03 · 最新观测版本
AnyBodyCodec: A Shared Native Interface for Body-Model Conversion, Extension, and Humanoid Control
Parametric body models expose incompatible pose and shape controls, tying humanoid policies to particular input formats. AnyBodyCodec learns a shared representation through native conversion, then reuses it for new body models and control with its core frozen. Encoders map MHR, SMPL-X, and SOMA to aligned slots; native decoders recover target controls. The 1.090M-parameter converter covers nine routes and reaches 16.801 mm input-reference MPJPE across six cross routes: the 2.887M Transformer bank reaches 16.390 mm and its parameter-matched version 18.866 mm. Three measured routes take 7.43-7.67 ms on an RTX 4090. Adding ANNY shows that comparable conversion accuracy can accompany different action consistency under one frozen controller. Under a matched PPO budget, aligned slots support 60.78% full-action success across three formats. Separate 160-hour training reaches 66.10% source-weighted validation success, and the controller is deployed qualitatively on a physical G1 through three visual front ends. Together, these results establish reuse through both native geometric fidelity and downstream policy compatibility.
查看此版本解读 →查看此版本原文 ↗