Beyond Outlier Rejection: Transient-Aware Reconstruction of Multi-Stack MRI

首次提交 2026-11-20 19:50
版本更新 2026-11-20 19:50
雷达观测 2026-11-24 11:45
arXiv ↗PDF ↗

摘要

Clinical MRI typically acquires the organ of interest as consecutive stacks of 2D slices in different orientations. Reconstruction methods such as SVRTK and NeSVoR fuse them into one volume and down-weight what does not fit, although in living tissue the change during the scan is often the signal itself and can contain clinically relevant physiological information, such as fetal motion and uterine contraction. We propose an analysis-by-synthesis decomposition that explains every acquired voxel through its exact acquisition geometry as a static anatomy shared by all stacks, a rigid and smooth non-rigid motion per stack, and a sparse transient field per stack for changes during one acquisition only. A robust reweighting keeps such changes out of the anatomy. The model is fitted per subject without training data, with one configuration for all datasets. On a digital phantom with known ground truth, static changes are kept entirely in the anatomy, and the transient field of the stack that saw a transient recovers 68% of it at 12mm radius. From identical inputs, the anatomy predicts held-out stacks better than SVRTK and NeSVoR on uterine (NCC 0.897 against 0.874 and 0.863, 123 patients) and on prostate MRI from unseen sites and scanners (0.847 against 0.795 and 0.757, 85 patients), and on fetal brain MRI as well as SVRTK and better than NeSVoR (0.771 against 0.763 and 0.747, 83 fetuses). The transient fields flag corrupted fetal slices with an AUROC of 0.94 against expert raters. As the input of a frozen anomaly detector trained on healthy subjects only, the anatomy localizes radiologist-delineated uterine lesions better than the SVRTK and NeSVoR volumes (AUROC 0.76 against 0.71 and 0.71, 37 patients).

作者备注:11 pages, 6 Figures

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只收录了一个版本。收录下一版后,可以对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-20 19:50 · 最新观测版本

Beyond Outlier Rejection: Transient-Aware Reconstruction of Multi-Stack MRI

Clinical MRI typically acquires the organ of interest as consecutive stacks of 2D slices in different orientations. Reconstruction methods such as SVRTK and NeSVoR fuse them into one volume and down-weight what does not fit, although in living tissue the change during the scan is often the signal itself and can contain clinically relevant physiological information, such as fetal motion and uterine contraction. We propose an analysis-by-synthesis decomposition that explains every acquired voxel through its exact acquisition geometry as a static anatomy shared by all stacks, a rigid and smooth non-rigid motion per stack, and a sparse transient field per stack for changes during one acquisition only. A robust reweighting keeps such changes out of the anatomy. The model is fitted per subject without training data, with one configuration for all datasets. On a digital phantom with known ground truth, static changes are kept entirely in the anatomy, and the transient field of the stack that saw a transient recovers 68% of it at 12mm radius. From identical inputs, the anatomy predicts held-out stacks better than SVRTK and NeSVoR on uterine (NCC 0.897 against 0.874 and 0.863, 123 patients) and on prostate MRI from unseen sites and scanners (0.847 against 0.795 and 0.757, 85 patients), and on fetal brain MRI as well as SVRTK and better than NeSVoR (0.771 against 0.763 and 0.747, 83 fetuses). The transient fields flag corrupted fetal slices with an AUROC of 0.94 against expert raters. As the input of a frozen anomaly detector trained on healthy subjects only, the anatomy localizes radiologist-delineated uterine lesions better than the SVRTK and NeSVoR volumes (AUROC 0.76 against 0.71 and 0.71, 37 patients).

查看此版本解读 →查看此版本原文 ↗