← 研踪 PaperTrailarXiv:2611.29426 · v1
Phase-Conditioned Action Contracts for Auditable Microsurgical Control
首次提交 2026-11-22 20:04
版本更新 2026-11-22 20:04
雷达观测 2026-11-24 12:47
摘要
Staged robotic procedures may reuse a fixed-dimensional policy output even though the admissible motions and physical meanings of its coordinates change across phases. We call this action-semantic shift. To address it, we propose a phase-conditioned executable policy that separates learned action proposal from deterministic command formation. Phase-specific heads generate proposals, while an action contract removes inadmissible components, enforces state-dependent bounds, and decodes the remaining action into phase-dependent task-space commands. We further introduce failure-focused local repair and a read-only provenance trace for exact command replay and rule-level auditing. Across three held-out retinal-injection evaluation blocks, our method achieves procedural completion and success within , with no hard violations. Applying the contract and decoder to the same frozen Correction network raises completion from to . The trace exactly reconstructs 96,350 commands, and all 1,996 binding interventions follow their declared effects. These results show the importance of explicit executable action semantics for auditable staged microsurgical control.
作者备注:14 pages
观测到的版本
相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。
v1 · 2026-11-22 20:04 · 最新观测版本
Phase-Conditioned Action Contracts for Auditable Microsurgical Control
Staged robotic procedures may reuse a fixed-dimensional policy output even though the admissible motions and physical meanings of its coordinates change across phases. We call this action-semantic shift. To address it, we propose a phase-conditioned executable policy that separates learned action proposal from deterministic command formation. Phase-specific heads generate proposals, while an action contract removes inadmissible components, enforces state-dependent bounds, and decodes the remaining action into phase-dependent task-space commands. We further introduce failure-focused local repair and a read-only provenance trace for exact command replay and rule-level auditing. Across three held-out retinal-injection evaluation blocks, our method achieves procedural completion and success within , with no hard violations. Applying the contract and decoder to the same frozen Correction network raises completion from to . The trace exactly reconstructs 96,350 commands, and all 1,996 binding interventions follow their declared effects. These results show the importance of explicit executable action semantics for auditable staged microsurgical control.
查看此版本解读 →查看此版本原文 ↗