Reconstructing 3D+t Cardiovascular Flow From Sparse Planar Velocity Fields With Neural Fields

首次提交 2026-11-23 22:43
版本更新 2026-11-23 22:43
雷达观测 2026-11-24 14:49
arXiv ↗PDF ↗

摘要

Reconstructing time-resolved three-dimensional (3D+t) cardiovascular flow from sparse planar measurements is challenging because each plane observes only the two in-plane velocity components, on a small part of the volume. We propose a plane-aware neural-field framework that learns a continuous 3D velocity field from space and time coordinates through a per-plane projection, and then investigate the potential benefits of physics constraints. We evaluate the framework on computational aortic and aneurysm datasets, and on planes resampled from a real cardiac 4D Flow MRI scan. A plain multi-layer perceptron (MLP) was more accurate than classical radial basis function (RBF) interpolation on both computational datasets. For the aorta, a physics-constrained SIREN (PC-SIREN) reduced the rRMSE further to 0.37560.3756, compared with 0.42730.4273 for the plain MLP and 0.72560.7256 for RBF, and it was the most accurate model in every anatomical segment of the MRI data. For the aneurysms the plain MLP remained the most accurate model, with an rRMSE of 0.070.07 to 0.160.16 against 0.550.55 to 0.710.71 for PC-SIREN. Further experiments investigated scanning configuration, number of scans, and spatial resolution. These findings show that continuous neural fields can reconstruct volumetric cardiovascular flow from sparse planar measurements, and that physics constraints have to be matched to the flow.

作者备注:10 pages, 6 figures

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只收录了一个版本。收录下一版后,可以对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-23 22:43 · 最新观测版本

Reconstructing 3D+t Cardiovascular Flow From Sparse Planar Velocity Fields With Neural Fields

Reconstructing time-resolved three-dimensional (3D+t) cardiovascular flow from sparse planar measurements is challenging because each plane observes only the two in-plane velocity components, on a small part of the volume. We propose a plane-aware neural-field framework that learns a continuous 3D velocity field from space and time coordinates through a per-plane projection, and then investigate the potential benefits of physics constraints. We evaluate the framework on computational aortic and aneurysm datasets, and on planes resampled from a real cardiac 4D Flow MRI scan. A plain multi-layer perceptron (MLP) was more accurate than classical radial basis function (RBF) interpolation on both computational datasets. For the aorta, a physics-constrained SIREN (PC-SIREN) reduced the rRMSE further to 0.37560.3756, compared with 0.42730.4273 for the plain MLP and 0.72560.7256 for RBF, and it was the most accurate model in every anatomical segment of the MRI data. For the aneurysms the plain MLP remained the most accurate model, with an rRMSE of 0.070.07 to 0.160.16 against 0.550.55 to 0.710.71 for PC-SIREN. Further experiments investigated scanning configuration, number of scans, and spatial resolution. These findings show that continuous neural fields can reconstruct volumetric cardiovascular flow from sparse planar measurements, and that physics constraints have to be matched to the flow.

查看此版本解读 →查看此版本原文 ↗