Reconstructing 3D+t Cardiovascular Flow From Sparse Planar Velocity Fields With Neural Fields
首次提交 2026-11-23 22:43
版本更新 2026-11-23 22:43
雷达观测 2026-11-24 14:49
摘要
Reconstructing time-resolved three-dimensional (3D+t) cardiovascular flow from sparse planar measurements is challenging because each plane observes only the two in-plane velocity components, on a small part of the volume. We propose a plane-aware neural-field framework that learns a continuous 3D velocity field from space and time coordinates through a per-plane projection, and then investigate the potential benefits of physics constraints. We evaluate the framework on computational aortic and aneurysm datasets, and on planes resampled from a real cardiac 4D Flow MRI scan. A plain multi-layer perceptron (MLP) was more accurate than classical radial basis function (RBF) interpolation on both computational datasets. For the aorta, a physics-constrained SIREN (PC-SIREN) reduced the rRMSE further to , compared with for the plain MLP and for RBF, and it was the most accurate model in every anatomical segment of the MRI data. For the aneurysms the plain MLP remained the most accurate model, with an rRMSE of to against to for PC-SIREN. Further experiments investigated scanning configuration, number of scans, and spatial resolution. These findings show that continuous neural fields can reconstruct volumetric cardiovascular flow from sparse planar measurements, and that physics constraints have to be matched to the flow.
作者备注:10 pages, 6 figures
观测到的版本
相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。
v1 · 2026-11-23 22:43 · 最新观测版本
Reconstructing 3D+t Cardiovascular Flow From Sparse Planar Velocity Fields With Neural Fields
Reconstructing time-resolved three-dimensional (3D+t) cardiovascular flow from sparse planar measurements is challenging because each plane observes only the two in-plane velocity components, on a small part of the volume. We propose a plane-aware neural-field framework that learns a continuous 3D velocity field from space and time coordinates through a per-plane projection, and then investigate the potential benefits of physics constraints. We evaluate the framework on computational aortic and aneurysm datasets, and on planes resampled from a real cardiac 4D Flow MRI scan. A plain multi-layer perceptron (MLP) was more accurate than classical radial basis function (RBF) interpolation on both computational datasets. For the aorta, a physics-constrained SIREN (PC-SIREN) reduced the rRMSE further to , compared with for the plain MLP and for RBF, and it was the most accurate model in every anatomical segment of the MRI data. For the aneurysms the plain MLP remained the most accurate model, with an rRMSE of to against to for PC-SIREN. Further experiments investigated scanning configuration, number of scans, and spatial resolution. These findings show that continuous neural fields can reconstruct volumetric cardiovascular flow from sparse planar measurements, and that physics constraints have to be matched to the flow.
查看此版本解读 →查看此版本原文 ↗