跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2611.32890 · v2

Biomechanically Grounded Prediction of Selective Motor Control and Clinical Outcomes from Infant Video

首次提交 2026-11-25 00:20
版本更新 2026-11-25 12:36
雷达观测 2026-11-26 11:26
arXiv ↗PDF ↗

摘要

Early identification of cerebral palsy (CP) relies on observational assessments of spontaneous infant movement, such as the General Movement Assessment (GMA) and the Baby Observational Selective Control AppRaisal (BabyOSCAR), which require trained raters and substantial scoring time. Existing automated approaches derive hand-engineered features from two-dimensional keypoints, which describe image-plane motion rather than the three-dimensional behavior of individual joints. We present Baby Biomechanical 3D Body (BB3D), an infant-adapted, biomechanical pipeline that estimates joint-angle trajectories from single-camera video. Against a multi-view markerless motion capture reference in 17 infants, BB3D's median Procrustes-aligned error was 17.5~mm for joint centers and 20.4~mm for marker sites. A spatio-temporal transformer, pretrained on BB3D joint-angle trajectories from 1k+ single-camera recordings, and fine-tuned on 550 videos from 350 infants, predicted each individual BabyOSCAR item with a mean within-site AUC of 0.79 and the BabyOSCAR total with a Spearman correlation of 0.86 on held-out recordings. Without being trained on diagnosis, the predicted total separated infants with CP from those without CP with an AUC of 0.86, exceeding a replicated two-dimensional feature classifier (0.67) but below the expert clinician rater's total (0.97). Predicted scores also carried information about functional ability and body distribution, though less than expert clinician scores. These results show that biomechanically grounded representations of monocular video can support scalable, joint-level assessment of selective motor control in infancy

作者备注:Submitted as a full contributed paper to IEEE International Conference on Rehabilitation Robotics (ICORR) 2027

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

仅对比实际观测的元数据,不代表 PDF 正文或实验变化。版本可能不连续;带删除线为移除,下划线为新增。

这两个版本的已观测标题、作者、分类、摘要和备注没有变化。正文是否变化请核对原文。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v2 · 2026-11-25 12:36 · 最新观测版本

Biomechanically Grounded Prediction of Selective Motor Control and Clinical Outcomes from Infant Video

Early identification of cerebral palsy (CP) relies on observational assessments of spontaneous infant movement, such as the General Movement Assessment (GMA) and the Baby Observational Selective Control AppRaisal (BabyOSCAR), which require trained raters and substantial scoring time. Existing automated approaches derive hand-engineered features from two-dimensional keypoints, which describe image-plane motion rather than the three-dimensional behavior of individual joints. We present Baby Biomechanical 3D Body (BB3D), an infant-adapted, biomechanical pipeline that estimates joint-angle trajectories from single-camera video. Against a multi-view markerless motion capture reference in 17 infants, BB3D's median Procrustes-aligned error was 17.5~mm for joint centers and 20.4~mm for marker sites. A spatio-temporal transformer, pretrained on BB3D joint-angle trajectories from 1k+ single-camera recordings, and fine-tuned on 550 videos from 350 infants, predicted each individual BabyOSCAR item with a mean within-site AUC of 0.79 and the BabyOSCAR total with a Spearman correlation of 0.86 on held-out recordings. Without being trained on diagnosis, the predicted total separated infants with CP from those without CP with an AUC of 0.86, exceeding a replicated two-dimensional feature classifier (0.67) but below the expert clinician rater's total (0.97). Predicted scores also carried information about functional ability and body distribution, though less than expert clinician scores. These results show that biomechanically grounded representations of monocular video can support scalable, joint-level assessment of selective motor control in infancy

查看此版本解读 →查看此版本原文 ↗
v1 · 2026-11-25 00:20

Biomechanically Grounded Prediction of Selective Motor Control and Clinical Outcomes from Infant Video

Early identification of cerebral palsy (CP) relies on observational assessments of spontaneous infant movement, such as the General Movement Assessment (GMA) and the Baby Observational Selective Control AppRaisal (BabyOSCAR), which require trained raters and substantial scoring time. Existing automated approaches derive hand-engineered features from two-dimensional keypoints, which describe image-plane motion rather than the three-dimensional behavior of individual joints. We present Baby Biomechanical 3D Body (BB3D), an infant-adapted, biomechanical pipeline that estimates joint-angle trajectories from single-camera video. Against a multi-view markerless motion capture reference in 17 infants, BB3D's median Procrustes-aligned error was 17.5~mm for joint centers and 20.4~mm for marker sites. A spatio-temporal transformer, pretrained on BB3D joint-angle trajectories from 1k+ single-camera recordings, and fine-tuned on 550 videos from 350 infants, predicted each individual BabyOSCAR item with a mean within-site AUC of 0.79 and the BabyOSCAR total with a Spearman correlation of 0.86 on held-out recordings. Without being trained on diagnosis, the predicted total separated infants with CP from those without CP with an AUC of 0.86, exceeding a replicated two-dimensional feature classifier (0.67) but below the expert clinician rater's total (0.97). Predicted scores also carried information about functional ability and body distribution, though less than expert clinician scores. These results show that biomechanically grounded representations of monocular video can support scalable, joint-level assessment of selective motor control in infancy

查看此版本解读 →查看此版本原文 ↗